Open this publication in new window or tab >>2006 (English)In: Optics and Spectroscopy, ISSN 0030-400X, E-ISSN 1562-6911, Vol. 100, no 6, p. 825-829Article in journal (Refereed) Published
Abstract [en]
This paper describes the technique and the results of measurement of the power and geometry of the VUV radiation beam from a dc capillary discharge in a mixture of krypton and xenon. The angular divergence of narrowband VUV radiation of the heteronuclear KrXe* molecule is shown to be narrower as compared to that of the discharge radiation in the range 200-1000 nm. The power of VUV radiation from a discharge tube 80 cm long is found to exceed 10 mW.
National Category
Atom and Molecular Physics and Optics
Identifiers
urn:nbn:se:uu:diva-25846 (URN)10.1134/S0030400X06060038 (DOI)000238546300003 ()
External cooperation:
Note
Original Russian Text by G.N. Gerasimov, B.E. Krylov, R. Hallin, A. Arnesen, 2006, published in Optika i Spektroskopiya, 2006, Vol. 100, No. 6, pp. 896–901.
2007-02-142007-02-142017-12-07Bibliographically approved