uu.seUppsala University Publications
Change search
Link to record
Permanent link

Direct link
BETA
Publications (10 of 15) Show all publications
Branger, E. (2019). Enhanced verification of irradiated nuclear fuel using Cherenkov light. In: : . Paper presented at FISA EURADWASTE Conference, ENEN PhD Event & Prize 2019, Pitesti, Romania, 5 June, 2019..
Open this publication in new window or tab >>Enhanced verification of irradiated nuclear fuel using Cherenkov light
2019 (English)Conference paper, Oral presentation with published abstract (Other academic)
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is one instrument available to authority inspectors to verify spent nuclear fuel assemblies in wet storage. Verification with the DCVD relies on a comparison between the measured Cherenkov light intensity to a predicted one. This work describes the development of an improved the prediction model, to further enhance the DCVD performance. By considering more fuel parameters in the predictions, predictions that are more accurate can be provided for fuel assemblies with a greater range of burnups, cooling times and irradiation histories. Furthermore, by considering the effect of the storage situation, the accuracy of the predictions can be further enhanced. By using the improved prediction model, the DCVD can be put into regular use to reliably verify fuel assemblies with a wider range of burnups and cooling times than before. The improved prediction model will be available to authority inspectors shortly.

National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-384857 (URN)
Conference
FISA EURADWASTE Conference, ENEN PhD Event & Prize 2019, Pitesti, Romania, 5 June, 2019.
Funder
Swedish Radiation Safety Authority, 2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2019-06-10 Created: 2019-06-10 Last updated: 2019-06-14Bibliographically approved
Zsolt, E., Mishra, V., Grape, S., Branger, E., Jansson, P. & Caldeira Balkeståhl, L. (2019). Investigating the gamma and neutron radiation around quivers for verification purposes. In: : . Paper presented at ESARDA Symposium 2019.
Open this publication in new window or tab >>Investigating the gamma and neutron radiation around quivers for verification purposes
Show others...
2019 (English)Conference paper, Oral presentation with published abstract (Other academic)
Abstract [en]

Before encapsulation of spent nuclear fuel in a geological repository, the fuels need to be verified fors afeguards purposes. This requirement applies to all spent fuel assemblies, including those with properties or designs that are especially challenging to verify. One such example are quivers, a new type of containers used to hold damaged spent fuel rods. After placing damaged rods inside the quivers, they are sealed with a thick lid and the water is removed. The lid is thick enough to significantly reduce the amount of the gamma radiation penetrating through it, which can make safeguards verification from the top using gamma techniques difficult.

In this paper we make a first feasibility study related to safeguards verification of quivers, aimed at investigating the gamma and neutron radiation field around a quiver using a simplified quiver geometry. The nuclide inventory of the rods placed in the quiver is calculated with Serpent and Origen-Arp, and the radiation transport is modeled with Serpent. The objective is to assess the capability of existing non-destructive assay instruments, measuring the gamma and/or neutron radiation from the object, to verify the content for nuclear safeguards purposes. The results show that the thick quiver lid attenuates the gamma radiation, thereby making gamma-radiation based verification from above the quiver difficult. Verification using neutron instruments above the quiver, or gamma and/or neutron instruments on the side may be possible. These results are in agreement with measurements of a BWR quiver using a DCVD, performed by the authors.

Keywords
quiver, safeguards verification, gamma radiation, neutron radiation, spent fuel, PWR, modeling
National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-389765 (URN)
Conference
ESARDA Symposium 2019
Available from: 2019-07-24 Created: 2019-07-24 Last updated: 2019-07-24
Grape, S., Branger, E., Elter, Z., Jansson, P. & Mishra, V. (2019). Machine learning in nuclear safeguards. In: : . Paper presented at Swedish Workshop on Data Science.
Open this publication in new window or tab >>Machine learning in nuclear safeguards
Show others...
2019 (English)Conference paper, Poster (with or without abstract) (Other academic)
Abstract [en]

•Before placing spent nuclear fuel in in a geological repository, they will be characterized and their declared properties will be verified.

•We have created large library of modelled spent nuclear fuel (SNF) assemblies and estimated their activity of gamma-ray emitting fission products, the early die-away time τ and the Cherenkov light intensity.

•We have used Random Forest regression to evaluate the capability to determine the fuel parameters initial enrichment (IE), burnup (BU) and cooling time (CT) using data from non-destructive assay (NDA) techniques

National Category
Other Physics Topics
Identifiers
urn:nbn:se:uu:diva-394881 (URN)
Conference
Swedish Workshop on Data Science
Funder
Swedish Radiation Safety Authority
Available from: 2019-10-10 Created: 2019-10-10 Last updated: 2019-10-10
Branger, E., Grape, S., Jansson, P. & Jacobsson Svärd, S. (2019). On the inclusion of light transport in prediction tools for Cherenkov light intensity assessment of irradiated nuclear fuel assemblies. Journal of Instrumentation, 14, Article ID T01010.
Open this publication in new window or tab >>On the inclusion of light transport in prediction tools for Cherenkov light intensity assessment of irradiated nuclear fuel assemblies
2019 (English)In: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 14, article id T01010Article in journal (Refereed) Published
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is a tool used to verify irradiated nuclear fuel assemblies in wet storage by imaging the Cherenkov light produced by the radiation emitted from the assemblies. It is frequently used for partial defect verification, verifying that part of an assembly has not been removed and/or replaced. In one of the verification procedures used, the detected total Cherenkov light intensities from a set of assemblies are compared to predicted intensities, which are calculated using operator declarations for the assemblies.

This work presents a new, time-efficient method to simulate DCVD images of fuel assemblies, allowing for estimations of the Cherenkov light production, transport and detection. Qualitatively, good agreement between simulated and measured images is demonstrated. Quantitatively, it is shown that relative intensity predictions based on simulated images are within 0.5% of corresponding predictions based solely on the production of Cherenkov light, neglecting light transport and detection. Consequently, in most cases it is sufficient to use predictions based on produced Cherenkov light, neglecting transport and detection, thus substantially reducing the time needed for simulations.

In a verification campaign, assemblies are grouped according to their type, and the relative measured and predicted intensities are compared in a group. By determining transparency factors, describing the fraction of Cherenkov light that is blocked by the top plate of an assembly, it is possible to adjust predictions based on the production of Cherenkov light to take the effect of the top plate into account. This procedure allows assemblies of the same type bit with different top plates to be compared with increased accuracy. The effect of using predictions adjusted with transparency factors were assessed experimentally on a set of Pressurized Water Reactor 17x17 assemblies having five different top plate designs. As a result of the adjustment, the agreement between measured and predicted relative intensities for the whole data set was enhanced, resulting in a reduction of an RMSE from 14.1% to 10.7%. It is expected that further enhancements may be achieved by introducing more detailed top-plate and spacer descriptions.

Keywords
Nuclear safeguards, Geant4, Cherenkov light, DCVD, Nuclear fuel
National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-357151 (URN)10.1088/1748-0221/14/01/T01010 (DOI)000457930800001 ()
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2018-08-13 Created: 2018-08-13 Last updated: 2019-03-05Bibliographically approved
Branger, E., Grape, S. & Jansson, P. (2019). Verifying PWR assemblies with rod cluster control assembly inserts using a DCVD. ESARDA Bulletin (58), 35-40
Open this publication in new window or tab >>Verifying PWR assemblies with rod cluster control assembly inserts using a DCVD
2019 (English)In: ESARDA Bulletin, ISSN 1977-5296, no 58, p. 35-40Article in journal (Refereed) Published
Abstract [en]

One of the instruments available to authority inspectors to measure and characterize the Cherenkov light emissions from irradiated nuclear fuel assemblies in wet storage is the Digital Cherenkov Viewing Device (DCVD). Based on the presence, characteristics and intensity of the Cherenkov light, the inspectors can verify that an assembly under study is not a dummy object, as well as perform partial defect verification of the assembly.

PWR assemblies are sometimes stored with a rod cluster control assembly (RCCA) inserted, which affects the Cherenkov light production and transport in the assembly. Such an insert will also block light from exiting the top of the fuel assembly, which will affect the light distribution and intensity of the Cherenkov light emissions. Whether or not this constitutes a problem when verifying the assemblies for gross or partial defects with a DCVD has not previously been investigated thoroughly.

In this work, the Cherenkov light intensity of a PWR 17x17 assembly with two different RCCA inserts were simulated and analysed, and compared to the Cherenkov light intensity from an assembly without an insert. For the studied assembly and insert types, the DCVD was found to be able to detect partial defects on the level of 50% in all studied cases with similar performance, though with a higher measurement uncertainty due to the reduced intensity when an RCCA insert is present. Consequently, for the studied assembly and insert types, assemblies with inserts can be verified with the same methodology as used for assemblies without inserts, with similar partial defect detection performance.

The simulation approach used also made it possible to investigate the minimum Cherenkov light intensity reduction resulting from partial defects of other levels than 50%, in the PWR 17x17 fuel assembly with and without RCCA inserts. The results for the simulations without an insert were in agreement with previous results, despite differences in substitution patterns, substitution materials, modeling software and analysis approach.

Keywords
DCVD, partial defect verification, Rod cluster control assembly, Cherenkov light, Geant4, nuclear fuel
National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-388553 (URN)
Available from: 2019-07-01 Created: 2019-07-01 Last updated: 2019-07-01
Branger, E. (2018). Enhancing the performance of the Digital Cherenkov Viewing Device: Detecting partial defects in irradiated nuclear fuel assemblies using Cherenkov light. (Doctoral dissertation). Uppsala: Acta Universitatis Upsaliensis
Open this publication in new window or tab >>Enhancing the performance of the Digital Cherenkov Viewing Device: Detecting partial defects in irradiated nuclear fuel assemblies using Cherenkov light
2018 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is an instrument used by authority safeguards inspectors to verify irradiated nuclear fuel assemblies in wet storage based on Cherenkov light emission. It is frequently used to verify that parts of an assembly have not been diverted, which is done by comparing the measured Cherenkov light intensity to a predicted one.

This thesis presents work done to further enhance the verification capability of the DCVD, and has focused on developing a second-generation prediction model (2GM), used to predict the Cherenkov light intensity of an assembly. The 2GM was developed to take into account the irradiation history, assembly type and beta decays, while still being usable to an inspector in-field. The 2GM also introduces a method to correct for the Cherenkov light intensity emanating from neighbouring assemblies. Additionally, a method to simulate DCVD images has been seamlessly incorporated into the 2GM.

The capabilities of the 2GM has been demonstrated on experimental data. In one verification campaign on fuel assemblies with short cooling time, the first-generation model showed a Root Mean Square error of 15.2% when comparing predictions and measurements. This was reduced by the 2GM to 7.8% and 8.1%, for predictions with and without near-neighbour corrections. A simplified version of the 2GM for single assemblies will be included in the next version of the official DCVD software, which will be available to inspectors shortly. The inclusion of the 2GM allows the DCVD to be used to verify short-cooled assemblies and assemblies with unusual irradiation history, with increased accuracy.

Experimental measurements show that there are situations when the intensity contribution due to neighbours is significant, and should be included in the intensity predictions. The image simulation method has been demonstrated to also allow the effect of structural differences in the assemblies to be considered in the predictions, allowing assemblies of different designs to be compared with enhanced accuracy.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2018. p. 97
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1708
Keywords
DCVD, Nuclear safeguards, Cherenkov light, Nuclear fuel assembly, Partial defect verification
National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-357578 (URN)978-91-513-0415-1 (ISBN)
Public defence
2018-10-12, Room 2005, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:00 (English)
Opponent
Supervisors
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2018-09-14 Created: 2018-08-17 Last updated: 2018-10-02
Branger, E., Grape, S., Jansson, P. & Jacobsson Svärd, S. (2018). Experimental evaluation of models for predicting Cherenkov light intensities from short-cooled nuclear fuel assemblies. Journal of Instrumentation, 13, Article ID P02022.
Open this publication in new window or tab >>Experimental evaluation of models for predicting Cherenkov light intensities from short-cooled nuclear fuel assemblies
2018 (English)In: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 13, article id P02022Article in journal (Refereed) Published
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is a tool used by nuclear safeguards inspectors to verify irradiated nuclear fuel assemblies in wet storage based on the recording of Cherenkov light produced by the assemblies. One type of verification involves comparing the measured light intensity from an assembly with a predicted intensity, based on assembly declarations. Crucial for such analyses is the performance of the prediction model used, and recently new modelling methods have been introduced to allow for enhanced prediction capabilities by taking the irradiation history into account, and by including the cross-talk radiation from neighbouring assemblies in the predictions.

In this work, the performance of three models for Cherenkov-light intensity prediction is evaluated by applying them to a set of short-cooled PWR 17x17 assemblies for which experimental DCVD measurements and operator-declared irradiation data was available; (1) a two-parameter model, based on total burnup and cooling time, previously used by the safeguards inspectors, (2) a newly introduced gamma-spectrum-based model, which incorporates cycle-wise burnup histories, and (3) the latter gamma-spectrum-based model with the addition to account for contributions from neighbouring assemblies.

The results show that the two gamma-spectrum-based models provide significantly higher precision for the measured inventory compared to the two-parameter model, lowering the standard deviation between relative measured and predicted intensities from 15.2% to 8.1% respectively 7.8%.

The results show some systematic differences between assemblies of different designs (produced by different manufacturers) in spite of their similar PWR 17x17 geometries, and possible ways are discussed to address such differences, which may allow for even higher prediction capabilities. Still, it is concluded that the gamma-spectrum-based models enable confident verification of the fuel assembly inventory at the currently used detection limit for partial defects, being a 30% discrepancy between measured and predicted intensities, while some false detection occurs with the two-parameter model. The results also indicate that the gamma-spectrum-based prediction methods are accurate enough that the 30% discrepancy limit could potentially be lowered.

Keywords
Cherenkov detectors; Search for radioactive and fissile materials; Simulation methods and programs; Radiation calculation
National Category
Subatomic Physics
Research subject
Physics
Identifiers
urn:nbn:se:uu:diva-346692 (URN)10.1088/1748-0221/13/02/P02022 (DOI)000425937900001 ()
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2018-03-20 Created: 2018-03-20 Last updated: 2018-08-17Bibliographically approved
Branger, E., Grape, S., Jansson, P. & Jacobsson Svärd, S. (2018). Experimental study of background subtraction in Digital Cherenkov Viewing Device measurements. Journal of Instrumentation, 13(8), Article ID T08008.
Open this publication in new window or tab >>Experimental study of background subtraction in Digital Cherenkov Viewing Device measurements
2018 (English)In: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 13, no 8, article id T08008Article in journal (Refereed) Published
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is an imaging tool used by authority inspectors for partial defect verification of nuclear fuel assemblies in wet storage, i.e. to verify that part of an assembly has not been diverted. One of the currently adopted verification procedures is based on quantitative measurements of the assembly's Cherenkov light emissions, and comparisons to an expected intensity, calculated based on operator declarations. A background subtraction of the intensity data in the recorded images is necessary for accurate quantitative measurements. The currently used background subtraction is aimed at removing an electronics-induced image-wide offset, but it is argued here that the currently adopted procedure may be insufficient.

It is recommended that a standard dark-frame subtraction should be used, to remove systematic pixel-wise background due to the electronics, replacing the currently used offset procedure. Experimental analyses show that a dark-frame subtraction would further enhance the accuracy and reliability of DCVD measurements. Furthermore, should ageing of the CCD chip result in larger systematic pixel-wise deviations over time, a dark-frame subtraction can ensure reliable measurements regardless of the age of the CCD chip. It can also help in eliminating any adverse effects of malfunctioning pixels. In addition to the background from electronic noise, ways to compensate for background from neighbouring fuel assemblies and ambient light are also discussed.

Keywords
Nuclear safeguards, Cherenkov light, DCVD, Nuclear fuel
National Category
Subatomic Physics
Research subject
Physics with specialization in Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-357150 (URN)10.1088/1748-0221/13/08/T08008 (DOI)000442556100001 ()
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2018-08-13 Created: 2018-08-13 Last updated: 2019-08-01Bibliographically approved
Branger, E., Grape, S., Jansson, P. & Jacobsson, S. (2018). Improved Cherenkov Light Prediction Model for Enhanced DCVD Performance. In: : . Paper presented at IAEA Symposium on International Safeguards: Building Future Safeguards Capabilities 5–8 November 2018, Vienna, Austria.
Open this publication in new window or tab >>Improved Cherenkov Light Prediction Model for Enhanced DCVD Performance
2018 (English)Conference paper, Published paper (Other academic)
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is an instrument used to verify irradiated nuclear fuel assemblies in wet storage based on the fuel’s Cherenkov light emissions. The DCVD is frequently used for partial defect verification, verifying that 50% or more of an assembly has not been diverted. The verification methodology is based on comparison of the measured Cherenkov light intensity to a predicted intensity, based on operator declarations.

For the last five years, a dedicated PhD project at Uppsala University has been aiming at enhancing and improving the verification capabilities when using the DCVD. The project is now approaching its end, and this paper summarizes the comprehensive work performed regarding improving the prediction capabilities.

A new prediction model has been developed, considering more fuel assembly details to ensure more accurate predictions. With the new model, the irradiation history of an assembly, the assembly design and the contributions from gamma and beta decays are taken into account. The model has also been extended to account for the radiation from neighbouring fuel assemblies, which can enter the assembly being measured and contribute to the measured Cherenkov light. The performance of the prediction model and the neighbour intensity prediction model has been validated against fuel measurements by the IAEA at a PWR facility with short-cooled fuel. The results show that the new model offers an improved prediction capability, allowing the fuel inventory to be verified with no fuel assemblies being identified as outliers requiring additional investigation. A simplified version of the prediction model will be implemented in the next DCVD software version, making it available to IAEA inspectors.

This development of the DCVD capabilities are in line with the fourth theme of the IAEA safeguards symposium, “Shaping the future of safeguards implementation”, by resolving challenges related to the DCVD and by extending the capabilities of the instrument.

Keywords
DCVD, Nuclear Fuel, Nuclear Safeguards
National Category
Subatomic Physics
Identifiers
urn:nbn:se:uu:diva-367334 (URN)
Conference
IAEA Symposium on International Safeguards: Building Future Safeguards Capabilities 5–8 November 2018, Vienna, Austria
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2018-11-30 Created: 2018-11-30 Last updated: 2019-03-07Bibliographically approved
Branger, E., Grape, S., Jacobsson, S., Jansson, P. & Andersson Sundén, E. (2017). Comparison of prediction models for Cherenkov light emissions from nuclear fuel assemblies. Journal of Instrumentation, 12, Article ID P06007.
Open this publication in new window or tab >>Comparison of prediction models for Cherenkov light emissions from nuclear fuel assemblies
Show others...
2017 (English)In: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 12, article id P06007Article in journal (Refereed) Published
Abstract [en]

The Digital Cherenkov Viewing Device (DCVD) is a tool used by nuclear safeguards inspectors to verify irradiated nuclear fuel assemblies in wet storage based on the Cherenkov light produced by the assembly. Verification that no rods have been substituted in the fuel, so-called partial-defect verification, is made by comparing the intensity measured with a DCVD with a predicted intensity, based on operator fuel declaration. The prediction model currently used by inspectors is based on simulations of Cherenkov light production in a BWR 8x8 geometry. This work investigates prediction models based on simulated Cherenkov light production in a BWR 8x8 and a PWR 17x17 assembly, as well as a simplified model based on a single rod in water. Cherenkov light caused by both fission product gamma and beta decays were considered.The simulations reveal that there are systematic differences between the models, most noticeably with respect to the fuel assembly cooling time. Consequently, a prediction model that is based on another fuel assembly configuration than the fuel type being measured, will result in systematic over or underestimation of short-cooled fuel as opposed to long-cooled fuel. While a simplified model may be accurate enough for fuel assemblies with fairly homogeneous cooling times, the prediction models may differ by up to 18 \,\% for more heterogeneous fuel. Accordingly, these investigations indicate that the currently used model may need to be exchanged with a set of more detailed, fuel-type specific models, in order minimize the model dependant systematic deviations.

Keywords
Cherenkov and transition radiation; Cherenkov detectors; Search for radioactive and; fissile materials; Interaction of radiation with matter
National Category
Subatomic Physics
Research subject
Physics with specialization in Applied Nuclear Physics
Identifiers
urn:nbn:se:uu:diva-309739 (URN)10.1088/1748-0221/12/06/P06007 (DOI)000405090600007 ()
Funder
Swedish Radiation Safety Authority, SSM2012-2750Swedish National Infrastructure for Computing (SNIC), p2007011
Available from: 2016-12-07 Created: 2016-12-07 Last updated: 2018-08-17Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0001-8207-3462

Search in DiVA