uu.seUppsala universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reproducibility of heart and thoracic wall positionin repeated deep inspiration breath holds forradiotherapy of left-sided breast cancer patients
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för immunologi, genetik och patologi, Medicinsk strålningsvetenskap.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för immunologi, genetik och patologi, Medicinsk strålningsvetenskap.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för immunologi, genetik och patologi, Experimentell och klinisk onkologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för immunologi, genetik och patologi, Medicinsk strålningsvetenskap.
2018 (engelsk)Inngår i: Acta Oncologica, ISSN 0284-186X, E-ISSN 1651-226X, Vol. 57, nr 10, s. 1318-1324Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Deep inspiration breath hold (DIBH) for radiotherapy of left-sided breast cancer patientscan effectively move the heart away from the target and reduce the heart dose compared to treatmentsin free breathing. This study aims to investigate the positional reproducibility of heart edge(HE) and thoracic wall (TW) during repeated DIBHs.

Material and methods: At three occasions, 11 left-sided breast cancer patients were CT imaged during6 minutes of repeated DIBHs with 60 cine CT series. The series were evenly distributed over threebed positions and for each bed position, the heart edge associated maximum heart distance (MHD)and thoracic wall-associated maximum lung distance (MLD) from a reference line were retrospectivelyanalyzed. The high temporal resolution of the CT series enabled intrinsic heart movements to beresolved from breath hold variations. A body surface laser scanning system continuously extracted thethorax height and displayed it in a pair of goggles for patient feedback. To check for ‘fake-breathing’movements, e.g. that the patient lifts its back from the couch to reach DIBH, the couch-to-spine distancewas also measured in all CT series.

Results: The analysis was done for 1432 cine CTs captured during 292 breath holds. The DIBH movedthe heart on average 15mm in medial direction compared with free breathing. For the three bed positionsstudied, the mean value of the max range, across all patients, was between 11–13mm for theMHD and 4–8mm for the MLD. The MHD variation due to breath hold variation was twice as large asthe MHD variation due to intrinsic heart movement. The couch-to-spine distance varied less than3mm for all fractions, i.e., no fake-breathing was discovered.

Conclusions: The heart edge and thoracic wall reproducibility was high in relation to the medial heartdisplacement induced by the DIBH.

sted, utgiver, år, opplag, sider
2018. Vol. 57, nr 10, s. 1318-1324
Emneord [en]
Radiotherapy, Deep Inspiration Breath Hold, Breast Cancer
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-358938DOI: 10.1080/0284186X.2018.1490027ISI: 000448595500006PubMedID: 30074438OAI: oai:DiVA.org:uu-358938DiVA, id: diva2:1243884
Tilgjengelig fra: 2018-08-31 Laget: 2018-08-31 Sist oppdatert: 2019-01-17bibliografisk kontrollert

Open Access i DiVA

fulltext(1221 kB)67 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1221 kBChecksum SHA-512
f4af72e2c9668fccc7a20a7f37ef816012e8f16a5f7195f21011328ffdcd5c3065b6a82727acfcc4afe8b7b7b6496b535875bec4a6422d9fbeeca44191c38ce4
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Wikström, KennethIsacsson, UlfNilsson, KristinaAhnesjö, Anders

Søk i DiVA

Av forfatter/redaktør
Wikström, KennethIsacsson, UlfNilsson, KristinaAhnesjö, Anders
Av organisasjonen
I samme tidsskrift
Acta Oncologica

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 67 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 50 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf