Motor unit number index: Guidelines for recording signals and their analysis
Natus Med Inc, Hopewell Jct, NY USA.
Med Coll Wisconsin, Milwaukee, WI 53226 USA.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Klinisk neurofysiologi. Univ Hosp, Uppsala, Sweden.
Kantonsspital St Gallen, St Gallen, Switzerland.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Muscle and Nerve, ISSN 0148-639X, E-ISSN 1097-4598, Vol. 58, nr 3, s. 374-380Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Introduction: This study proposes guidelines for motor unit number index (MUNIX) recording and analysis. Methods: MUNIX was measured in control participants and in patients with amyotrophic lateral sclerosis. Changes in MUNIX values due to E1 electrode position, number of surface electromyography interference pattern (SIP) epochs, SIP epoch duration, force of contraction, and outlier data points were investigated. Results: MUNIX depends on optimized compound muscle action potential (CMAP) amplitude. Individual muscles showed variations when the number of epochs was low or when the SIP duration was short. Longer SIP duration allowed better recognition of artifacts. MUNIX results were affected by SIP values at all force levels but was more affected when SIP area was low. Discussion: We recommend changing the E1 electrode position to maximize CMAP amplitude. Twenty or more SIP signals of 500-ms duration should be recorded by using force levels ranging from slight to maximum. Traces should be reviewed to identify and exclude signals with tremor or solitary spikes.

sted, utgiver, år, opplag, sider
2018. Vol. 58, nr 3, s. 374-380
Emneord [en]
artifacts, compound muscle action potential, guidelines, motor unit number index, MUNIX, surface EMG interference pattern, tremor
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-365670DOI: 10.1002/mus.26099ISI: 000444079300009PubMedID: 29427557OAI: oai:DiVA.org:uu-365670DiVA, id: diva2:1263175
Tilgjengelig fra: 2018-11-14 Laget: 2018-11-14 Sist oppdatert: 2018-11-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Stålberg, Erik

Søk i DiVA

Av forfatter/redaktør
Stålberg, Erik
Av organisasjonen
I samme tidsskrift
Muscle and Nerve

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 12 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf