The use of impedance cardiography for optimizing the interventricular stimulation interval in cardiac resynchronization therapy-a comparison with left ventricular contractility
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Medicin. (Arytmi)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Medicin. (Arytmi)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Medicin. (Arytmi)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Medicin. (Arytmi)
Vise andre og tillknytning
2009 (engelsk)Inngår i: Journal of Interventional Cardiac Electrophysiology, ISSN 1383-875X, E-ISSN 1572-8595, Vol. 25, nr 3, s. 223-228Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The present study aimed to assess whether impedance cardiography (IC) can correctly identify the optimal interventricular (VV) pacing interval in cardiac resynchronization therapy (CRT). Twenty four patients received a biventricular pacemaker and underwent IC for cardiac output (CO) measurements to identify the optimal VV interval. Invasive measurements of left ventricular (LV) dP/dt(max) were used as a reference. During optimization the VV interval was changed with 20 ms steps from +80 (LV pre-excitation) to-80 ms (RV pre-excitation). The optimal VV interval was defined as the one that resulted in the highest LV dP/dt(max) value and the highest CO obtained by IC, respectively. During simultaneous biventricular pacing both LV dP/dt(max) and CO increased (mean 16.6% and 16.2%, respectively) as compared to baseline. Biventricular pacing with optimized VV intervals resulted in a further absolute increase of LV dP/dt (max) and CO (5.6% and 41.3%, respectively). The average decrease in LV dP/dt(max) was 79.6 +/- 51.6 mmHg/s when the optimal VV interval was programmed according to the IC measurements. Cross spectral analysis showed no correlation between the optimal VV intervals identified by the two methods (p > 0.05) and identical optimal VV intervals were identified in only six of the 24 patients. When broader VV time intervals were compared the correlation between the two methods was statistically significant (p = 0,0166). In conclusion, the use of IC for VV interval optimization is questionable since these optimized time intervals do not seem to correlate well with those obtained by measuring LV dP/dt.

sted, utgiver, år, opplag, sider
2009. Vol. 25, nr 3, s. 223-228
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-103115DOI: 10.1007/s10840-009-9367-xISI: 000268581800013PubMedID: 19263200OAI: oai:DiVA.org:uu-103115DiVA, id: diva2:217449
Tilgjengelig fra: 2009-05-14 Laget: 2009-05-14 Sist oppdatert: 2022-04-29bibliografisk kontrollert
Inngår i avhandling
1. Cardiac Resynchronization Therapy Optimization: Comparison and Evaluation of Non-invasive Methods
Åpne denne publikasjonen i ny fane eller vindu >>Cardiac Resynchronization Therapy Optimization: Comparison and Evaluation of Non-invasive Methods
2012 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The general purpose of this thesis was to investigate new cardiac resynchronization therapy (CRT) optimization techniques and to assess their reliability when compared to invasive measurements of left ventricular contractility (LV dP/dtmax).We first assessed whether cardiac output (CO) measured by trans-thoracic impedance cardiography could correctly identify the optimal interventricular (VV) pacing interval while using invasive measurements of LV dP/dtmax as reference. We did not find any significant statistical correlation between the two optimizing methods when their corresponding optimal VV intervals were compared.

We also tested the hypothesis that measurements of right ventricular contractility (RV dP/dtmax) could be used to guide VV delay optimization in CRT. The comparison of optimal VV intervals obtained from the left and right ventricular dP/dtmax did not show a statistically significant correlation; however, a positive correlation was found when broader VV intervals were evaluated and we concluded that this finding deserves further investigation.

An interesting alternative for CRT optimization is the use of device integrated algorithms or sensors capable to adapt the CRT settings to the current needs of the individual patient. In this respect we investigated the use of cardiogenic impedance (CI) measurements obtained through the CRT-D device as a method for CRT optimization with invasive measurements of LV dP/dtmax as a reference. Our results showed that CI could be measured through the device after implantation and that a patient-specific impedance-based prediction model was capable to accurately predict the optimal AV and VV delays. To follow up on these positive results we re-evaluated the patient-specific impedance-based prediction models 24 hours post implantation and investigated the possibility of calibrating them using parameters derived from non-invasive measurements of arterial pressure obtained by finger pelthysmography at implantation.The results showed that the patient-specific impedance-based prediction models did not perform as well on the follow-up data as they did on the data from implantation day and that they correlated poorly with plethysmographic parameters.

Our studies suggest that novel methods for CRT optimization should be thoroughly evaluated and compared to established measures of left ventricular function prior to introduction into clinical practice.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2012. s. 52
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 802
Emneord
cardiac resynchronization therapy, device optimization, left ventricular contractility
HSV kategori
Forskningsprogram
Kardiologi
Identifikatorer
urn:nbn:se:uu:diva-179785 (URN)978-91-554-8450-7 (ISBN)
Disputas
2012-10-05, Robergsalen, Akademiska Sjukhuset, Ing. 40, Uppsala, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2012-09-14 Laget: 2012-08-22 Sist oppdatert: 2013-01-22bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed
Av organisasjonen
I samme tidsskrift
Journal of Interventional Cardiac Electrophysiology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 449 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf