uu.seUppsala universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Model-based mapping of fat unsaturation and chain length by chemical shift imaging: phantom validation and in vivo feasibility
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
2012 (engelsk)Inngår i: Magnetic Resonance in Medicine, ISSN 0740-3194, E-ISSN 1522-2594, Vol. 68, nr 6, s. 1815-1827Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Knowledge about the triglyceride (fat) 1H spectrum enables quantitative determination of several triglyceride characteristics. This work describes a model-based chemical shift imaging method that separates water and fat signal and provides maps of three triglyceride quantities: fatty acid carbon chain length (CL), number of double bond pairs (ndb), and number of methylene-interrupted double bonds (nmidb). The method was validated by imaging a phantom containing ten different oils using 1.5 T and 3.0 T clinical scanners, with gas-liquid chromatography (GLC) as reference. Repeated acquisitions demonstrated high reproducibility of the method. Statistical tests of correlation and linear regression were performed to examine the accuracy of the method. Significant correlation was found at both field strengths for all three quantities, and high correlation (r2 > 0.96) was found for measuring ndb and nmidb. Feasibility of the method for in vivo imaging of the thigh was demonstrated at both field strengths. The estimates of ndb and nmidb in subcutaneous adipose tisse were in agreement with literature values, while CL appears overestimated. The method has potential use in large-scale cross-sectional and longitudinal studies of triglyceride composition, and its relation to diet and various diseases.

sted, utgiver, år, opplag, sider
2012. Vol. 68, nr 6, s. 1815-1827
Emneord [en]
water/fat separation, chemical shift imaging, quantitative MRI, fat unsaturation, triglyceride mapping, fatty acid composition
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-158098DOI: 10.1002/mrm.24196ISI: 000311398600015PubMedID: 22334300OAI: oai:DiVA.org:uu-158098DiVA, id: diva2:437953
Tilgjengelig fra: 2011-08-31 Laget: 2011-08-31 Sist oppdatert: 2017-12-08bibliografisk kontrollert
Inngår i avhandling
1. Separation of Water and Fat Signal in Magnetic Resonance Imaging: Advances in Methods Based on Chemical Shift
Åpne denne publikasjonen i ny fane eller vindu >>Separation of Water and Fat Signal in Magnetic Resonance Imaging: Advances in Methods Based on Chemical Shift
2011 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Magnetic resonance imaging (MRI) is one of the most important diagnostic tools of modern healthcare. The signal in medical MRI predominantly originates from water and fat molecules. Separation of the two components into water-only and fat-only images can improve diagnosis, and is the premier non-invasive method for measuring the amount and distribution of fatty tissue.

Fat-water imaging (FWI) enables fast fat/water separation by model-based estimation from chemical shift encoded data, such as multi-echo acquisitions. Qualitative FWI is sufficient for visual separation of the components, while quantitative FWI also offers reliable estimates of the fat percentage in each pixel. The major problems of current FWI methods are long acquisition times, long reconstruction times, and reconstruction errors that degrade image quality.

In this thesis, existing FWI methods were reviewed, and novel fully automatic methods were developed and evaluated, with a focus on fast 3D image reconstruction. All MRI data was acquired on standard clinical scanners.

A triple-echo qualitative FWI method was developed for the specific application of 3D whole-body imaging. The method was compared with two reference methods, and demonstrated superior image quality when evaluated in 39 volunteers.

The problem of qualitative FWI by dual-echo data with unconstrained echo times was solved, allowing faster and more flexible image acquisition than conventional FWI. Feasibility of the method was demonstrated in three volunteers and the noise performance was evaluated.

Further, a quantitative multi-echo FWI method was developed. The signal separation was based on discrete whole-image optimization. Fast 3D image reconstruction with few reconstruction errors was demonstrated by abdominal imaging of ten volunteers.

Lastly, a method was proposed for quantitative mapping of average fatty acid chain length and degree of saturation. The method was validated by imaging different oils, using gas-liquid chromatography (GLC) as the reference. The degree of saturation agreed well with GLC, and feasibility of the method was demonstrated in the thigh of a volunteer.

The developed methods have applications in clinical settings, and are already being used in several research projects, including studies of obesity, dietary intervention, and the metabolic syndrome.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2011. s. 85
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 701
Emneord
Magnetic resonance imaging, digital image reconstruction, chemical shift imaging, water and fat separation, Dixon method, fat suppression, quantitative MRI, whole-body MRI, fatty acid composition, fat unsaturation, triglycerides, adipose tissue, liver fat, T2* mapping
HSV kategori
Forskningsprogram
Radiologi
Identifikatorer
urn:nbn:se:uu:diva-158111 (URN)978-91-554-8154-4 (ISBN)
Disputas
2011-10-21, Hedstrandsalen, Entrance 70, Uppsala University Hospital, Uppsala, 13:15 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2011-09-29 Laget: 2011-08-31 Sist oppdatert: 2011-11-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Berglund, JohanAhlström, HåkanKullberg, Joel

Søk i DiVA

Av forfatter/redaktør
Berglund, JohanAhlström, HåkanKullberg, Joel
Av organisasjonen
I samme tidsskrift
Magnetic Resonance in Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 725 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf