uu.seUppsala universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Fysioterapi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Fysioterapi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Sjukgymnastik. Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Lungmedicin och allergologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Fysioterapi.
2015 (engelsk)Inngår i: Physiotherapy Theory and Practice, ISSN 0959-3985, E-ISSN 1532-5040, Vol. 31, nr 3, s. 194-199Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Objective: To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency.

Design: Test-retest study.

Subjects: A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot Marie Tooth disease.

Method: The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated.

Results: The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2).

Conclusion: The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

sted, utgiver, år, opplag, sider
2015. Vol. 31, nr 3, s. 194-199
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-245741DOI: 10.3109/09593985.2014.982776ISI: 000352858300007PubMedID: 25418018OAI: oai:DiVA.org:uu-245741DiVA, id: diva2:791411
Tilgjengelig fra: 2015-02-27 Laget: 2015-02-27 Sist oppdatert: 2017-12-04bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Hellström, KarinEmtner, MargaretaAnens, Elisabeth

Søk i DiVA

Av forfatter/redaktør
Hellström, KarinEmtner, MargaretaAnens, Elisabeth
Av organisasjonen
I samme tidsskrift
Physiotherapy Theory and Practice

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 1341 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf