uu.seUppsala universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
2001 (engelsk)Inngår i: European spine journal, ISSN 0940-6719, E-ISSN 1432-0932, Vol. 10, nr 4, s. 334-9Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Loosening of the pedicle screws with subsequent non-union or loss of correction is a frequent problem in spinal instrumentation. In a clinical pilot study, coating of pedicle screws with plasma-sprayed hydroxyapatite (HA) resulted in a significant increase of removal torque. An experimental study was performed to investigate the effects of HA coating on the pull-out resistance. Thirteen sheep were operated on with destabilising laminectomies at two levels, L2-L3 and L4-L5. Two instrumentations with four pedicle screws in each were used for stabilisation. Uncoated screws (stainless steel) or the same type of screws coated with plasma-sprayed HA were used in either the upper or the lower instrumentation in a randomised fashion. Four sheep were examined immediately after the application of the screws, three sheep at 6 weeks and four sheep at 12 weeks. Two sheep were euthanised early due to complications. The pull-out resistance was recorded in two HA-coated and two standard screws in each animal. The maximum pull-out resistance was higher for the HA-coated screws at 0 weeks (P< 0.02) and at 12 weeks (P<0.01) when compared to the uncoated screws, while there was no significant difference between the groups at 6 weeks. We believe that the higher pull-out resistance for HA-coated screws at 0 weeks was mainly caused by differences in surface roughness, while the difference at 12 weeks was due to a favourable bone reaction around the HA-coated screws. At 12 weeks, the average stiffness was significantly higher for the HA-coated screws, while there was no significant differences in stiffness between the two screw types at 0 and 6 weeks. Energy to failure was significantly higher for coated screws when compared to the uncoated screws at all three time points. HA coating improves fixation of loaded pedicle screws, with increased pull-out resistance and reduced risk of loosening.

sted, utgiver, år, opplag, sider
2001. Vol. 10, nr 4, s. 334-9
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-63168DOI: 10.1007/s005860100291PubMedID: 11563620OAI: oai:DiVA.org:uu-63168DiVA, id: diva2:91079
Tilgjengelig fra: 2008-10-17 Laget: 2008-10-17 Sist oppdatert: 2017-11-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Olerud, ClaesLarsson, Sune

Søk i DiVA

Av forfatter/redaktør
Olerud, ClaesLarsson, Sune
Av organisasjonen
I samme tidsskrift
European spine journal

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 355 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf