Characteristics of leader pulses in positive ground flashes in Sweden
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära. Faculty of Electrical Engineering, Centre for Electrical Power Engineering Studies, Universiti Teknologi Mara, 40450 Shah Alam, Selangor, Malaysia. (Åskforskning)
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära. (Åskforskning)
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära. (Åskforskning)
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära. (Åskforskning)ORCID-id: 0000-0003-1377-1923
Vise andre og tillknytning
2017 (engelsk)Inngår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 153, s. 3-9Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper presents the characteristics of the electric field pulses observed during leader propagation in positive ground flashes. We analysed in detail the electric field changes occurring just before the first return stroke in 51 positive ground flashes during 2014 summer thunderstorms in Uppsala, Sweden. Pronounced leader pulses (having the same polarity as the return stroke) were observed in 22% of the cases. They were observed to occur within 1.4 ms before the first return stroke. Interpulse duration ranged from 13.3 to 50.3 μs with a mean value of 24.7 μs. The peak amplitude of the leader pulses relative to the return stroke peak ranged from 2.7 to 17.8%. The presence of these pulses shows that the leaders propagate in a stepped manner. Based on the leader pulses’ time of initiation and average speed of the leader, the distance travelled by the leader was also estimated. One case of positive ground flash preceded by opposite polarity leader pulses just before the return stroke is also reported. To the best of our knowledge, this is the first time that such a case in positive ground flashes is reported. We suggest that these opposite polarity leader pulses are due to the negatively-charged leader branch of a bi-directional leader inside the cloud that propagates towards observation point.

sted, utgiver, år, opplag, sider
2017. Vol. 153, s. 3-9
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot atmosfäriska urladdningar
Identifikatorer
URN: urn:nbn:se:uu:diva-293059DOI: 10.1016/j.epsr.2016.11.026ISI: 000413380500002OAI: oai:DiVA.org:uu-293059DiVA, id: diva2:927311
Tilgjengelig fra: 2016-05-11 Laget: 2016-05-11 Sist oppdatert: 2019-07-16bibliografisk kontrollert
Inngår i avhandling
1. Features of the Electric Fields Generated by Lightning with Special Attention to Positive Ground Flashes
Åpne denne publikasjonen i ny fane eller vindu >>Features of the Electric Fields Generated by Lightning with Special Attention to Positive Ground Flashes
2017 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis focuses on the main processes in positive ground flashes and the distant lightning environment for both positive and negative ground flashes. It presents the characteristics of the preliminary breakdown pulses (PBPs), the characteristics of the electric field pulses observed during leader propagation, and the characteristics of the electric fields produced by the first and the subsequent return strokes. It also features the observations of distant positive and negative ground flashes at distances up to 1000 km. The results were based on electric field measurements conducted remotely during summer thunderstorms in Sweden in 2014.

We found that the majority of the positive ground flashes were preceded by PBPs. Some were preceded by more than one PBP train, and the parameter values for the subsequent PBP trains were found to be smaller than the values for the first PBP train. Three types of PBPs were also identified. The results suggest that the PBPs in positive ground flashes during summer thunderstorms in Sweden are weak, and the inverted dipole charge cloud configuration is consistent with our observation.

A small percentage of these positive ground flashes were observed to be preceded by pronounced leader pulses. The presence of these pulses suggests that the leaders propagate in a stepped manner. We inferred that these pulses were due to the upward-connecting negative leader since their characteristics were similar to those of a negative stepped leader. On the basis of the leader pulses’ time of initiation and the average speed of the leader, we estimated the distance travelled by the leader. One case of positive return stroke preceded by negative leader pulses was also observed, and the occurrence of these pulses was the first in positive ground flashes to be reported.

The majority of these positive ground flashes were found to be single-stroke. Comparison between the first and the subsequent return strokes showed that the average durations of the subsequent stroke parameters were smaller than that of the first strokes. The distances reported by the lightning location system suggest that the subsequent strokes probably created new terminations to ground. Two possible reasons were given to explain the reason for the shorter duration of the subsequent return strokes parameters compared to the first strokes.

Finally, observations of distant positive and negative ground flashes showed that the electric field waveforms have a typical shape, like a distorted ‘W’ (or distorted ‘M’ for negative ground flashes) followed by small oscillations. These small oscillations were more pronounced in negative ground flashes, especially at a greater distance. The heights of the ionospheric reflections estimated for both ground flashes were found to likely correspond to a D-layer of the ionosphere. Two possible reasons were suggested for the small oscillations observed in the waveforms.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2017. s. 49
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1588
Emneord
positive ground flashes, preliminary breakdown pulses, multiple-trains PBPs, positive leader, bidirectional leader, negative leader branch, subsequent return strokes, distant lightning
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot atmosfäriska urladdningar
Identifikatorer
urn:nbn:se:uu:diva-331885 (URN)978-91-513-0128-0 (ISBN)
Disputas
2017-12-11, Häggsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2017-11-20 Laget: 2017-10-20 Sist oppdatert: 2018-03-07

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Johari, DalinaCooray, VernonRahman, MahbuburHettiarachchi, PasanIsmail, Mohd Muzafar

Søk i DiVA

Av forfatter/redaktør
Johari, DalinaCooray, VernonRahman, MahbuburHettiarachchi, PasanIsmail, Mohd Muzafar
Av organisasjonen
I samme tidsskrift
Electric power systems research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 268 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf