Continuous subcutaneous glucose monitoring is accurate in term and near-term infants at risk of hypoglycaemia
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, Centrum för klinisk forskning i Sörmland (CKFD). Karolinska Institutet and University Hospital Huddinge, Stockholm, Sweden.ORCID-id: 0000-0001-9887-5160
Malarsjukhuset Hosp, Dept Paediat, Eskilstuna, Sweden.
Karolinska Inst, Stockholm, Sweden; Huddinge Univ Hosp, Stockholm, Sweden.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, Centrum för klinisk forskning i Sörmland (CKFD). Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kvinnors och barns hälsa, Pediatrik.
2016 (Engelska)Ingår i: Acta Paediatrica, ISSN 0803-5253, E-ISSN 1651-2227, Vol. 105, nr 8, s. 917-923Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

AIM: Postnatal hypoglycaemia increases the risk of adverse neurological outcomes in newborn infants, and adequate glucose control requires repetitive and painful blood sampling. This study evaluated a continuous glucose monitoring system (CGMS) that aims to improve glucose control and decrease the frequency of blood samples taken from neonates.

METHODS: CGMS sensors, which measure glucose values every five minutes and require calibration twice a day, were placed on 20 infants at risk of hypoglycaemia. The infants also underwent blood glucose sampling, and the blood glucose values were compared with CGMS values six times during the first 30 minutes after sampling.

RESULTS: We used 97/264 (37%) of the blood glucose values taken for the CGMS calibration. The highest accuracy, a mean of 0.22 (95% confidence interval 0.13-0.30 mmol/L), was found 15-19 minutes after sampling, due to the calibration process. No significant subcutaneous glucose time lag was detectable.

CONCLUSION: The CGMS system was an accurate and feasible method for glucose control, provided earlier detection of hypoglycaemia in newborn infants and reduced their exposure to procedural pain. The delay in calibration in infants was a new finding and needs to be taken into account when comparing CGMS readings to blood glucose values.

Ort, förlag, år, upplaga, sidor
2016. Vol. 105, nr 8, s. 917-923
Nyckelord [en]
Blood glucose, Continuous glucose monitoringsystem, Hypoglycaemia, Neon ate, Pain
Nationell ämneskategori
Pediatrik
Identifikatorer
URN: urn:nbn:se:uu:diva-304777DOI: 10.1111/apa.13479ISI: 000382741100024PubMedID: 27203555OAI: oai:DiVA.org:uu-304777DiVA, id: diva2:1033993
Tillgänglig från: 2016-10-10 Skapad: 2016-10-10 Senast uppdaterad: 2017-11-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Wackernagel, Dirk

Sök vidare i DiVA

Av författaren/redaktören
Wackernagel, DirkTindberg, Ylva
Av organisationen
Centrum för klinisk forskning i Sörmland (CKFD)Pediatrik
I samma tidskrift
Acta Paediatrica
Pediatrik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 382 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf