Regional lung ventilation and perfusion by electrical impedance tomography compared to single-photon emission computed tomography
Rhein Westfal TH Aachen, Philips Chair Med Informat Technol, Pauwelsstr 20, D-52074 Aachen, Germany;Univ Bonn, Dept Anaesthesiol & Intens Care Med, Sigmund Freud Str 25, D-53105 Bonn, Germany.
Univ Bonn, Dept Anaesthesiol & Intens Care Med, Sigmund Freud Str 25, D-53105 Bonn, Germany.
Univ Bonn, Dept Anaesthesiol & Intens Care Med, Sigmund Freud Str 25, D-53105 Bonn, Germany.
Univ Hosp, Dept Hosp Phys, Uppsala, Sweden.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Physiological Measurement, ISSN 0967-3334, E-ISSN 1361-6579, Vol. 39, nr 6, artikel-id 065004Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Objective: Electrical impedance tomography (EIT) is a noninvasive imaging modality that allows real-time monitoring of regional lung ventilation (<(V)over dot>) in intensive care patients at bedside. However, for improved guidance of ventilation therapy it would be beneficial to obtain regional ventilation-to-perfusion ratio (<(V)over dot> / <(Q)over dot>) by EIT.

Approach: In order to further explore the feasibility, we first evaluate a model-based approach, based on semi-negative matrix factorization and a gamma-variate model, to extract regional lung perfusion (<(Q)over dot>) from EIT measurements. Subsequently, a combined validation of both <(V)over dot> and <(Q)over dot> measured by EIT against single-photon emission computed tomography (SPECT) is performed on data acquired as part of a porcine animal trial. Four pigs were ventilated at two different levels of positive end-expiratory pressure (PEEP 0 and 15 cm H2O, respectively) in randomized order. Repeated injections of an EIT contrast agent (NaCl 10%) and simultaneous SPECT measurements of <(V)over dot> (81(m)Kr gas) and <(Q)over dot> (99(m)Tc-labeled albumin) were performed.

Main results: Both <(V)over dot> and <(Q)over dot> from EIT and SPECT were compared by correlation analysis. Very strong (r(2) = 0.94 to 0.95) correlations were found for <(V)over dot> and <(Q)over dot> in the dorsal-ventral direction at both PEEP levels. Moderate (r(2) = 0.36 to 0.46) and moderate to strong (r(2) = 0.61 to 0.82) correlations resulted for <(V)over dot> and <(Q)over dot> in the right-left direction, respectively.

Significance: The results of combined validation indicate that monitoring of <(V)over dot> and <(Q)over dot> by EIT is possible. However, care should be taken when trying to quantify <(V)over dot> / <(Q)over dot> by EIT, as imaging artefacts and model bias may void necessary spatial matching.

Ort, förlag, år, upplaga, sidor
IOP PUBLISHING LTD , 2018. Vol. 39, nr 6, artikel-id 065004
Nyckelord [en]
electrical impedance tomography, regional lung ventilation, regional lung perfusion, indicator dilution, functional imaging, gas exchange, single-photon emission computed tomography
Nationell ämneskategori
Fysiologi
Identifikatorer
URN: urn:nbn:se:uu:diva-358530DOI: 10.1088/1361-6579/aac7aeISI: 000435872300002PubMedID: 29794336OAI: oai:DiVA.org:uu-358530DiVA, id: diva2:1244829
Forskningsfinansiär
Deutsche Forschungsgemeinschaft (DFG), PU 219/2-1Tillgänglig från: 2018-09-03 Skapad: 2018-09-03 Senast uppdaterad: 2018-09-03Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Hedenstierna, Göran

Sök vidare i DiVA

Av författaren/redaktören
Hedenstierna, Göran
Av organisationen
Klinisk fysiologi
I samma tidskrift
Physiological Measurement
Fysiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 11 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf