uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Multiwavelength time-resolved near-infrared spectroscopy of the adult head: assessment of intracerebral and extracerebral absorption changes
Polish Acad Sci, Nalecz Inst Biocybemet & Biomed Engn, Trojdena 4, PL-02109 Warsaw, Poland.
Polish Acad Sci, Nalecz Inst Biocybemet & Biomed Engn, Trojdena 4, PL-02109 Warsaw, Poland;Lawson Hlth Res Inst, Imaging Div, London, ON N61 4172, Canada;Western Univ, Dept Med Biophys, London, ON N6A 51, Canada.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Polish Acad Sci, Nalecz Inst Biocybemet & Biomed Engn, Trojdena 4, PL-02109 Warsaw, Poland.
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Biomedical Optics Express, ISSN 2156-7085, E-ISSN 2156-7085, Vol. 9, nr 7, s. 2974-2993Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

An optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for the clinical assessment of brain perfusion at the bedside. We report on multiwavelength time-resolved diffuse reflectance spectroscopy measurements carried out on the head of a healthy adult during the intravenous administration of a bolus of ICG. Intracerebral and extracerebral changes in absorption were estimated from an analysis of changes in statistical moments (total number of photons, mean time of flight and variance) of the distributions of times of flight (DTOF) of photons recorded simultaneously at 16 wavelengths from the range of 650-850 nm using sensitivity factors estimated by diffusion approximation based on a layered model of the studied medium. We validated the proposed method in a series of phantom experiments and in-vivo measurements. The results obtained show that changes in the concentration of the ICG can be assessed as a function of time of the experiment and depth in the tissue. Thus, the separation of changes in ICG concentration appearing in intra-and extracerebral tissues can be estimated from optical data acquired at a single source-detector pair of fibers/fiber bundles positioned on the surface of the head.

Ort, förlag, år, upplaga, sidor
OPTICAL SOC AMER , 2018. Vol. 9, nr 7, s. 2974-2993
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-360194DOI: 10.1364/BOE.9.002974ISI: 000437460600007PubMedID: 29984079OAI: oai:DiVA.org:uu-360194DiVA, id: diva2:1247055
Tillgänglig från: 2018-09-11 Skapad: 2018-09-11 Senast uppdaterad: 2018-09-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Weigl, Wojciech

Sök vidare i DiVA

Av författaren/redaktören
Weigl, Wojciech
Av organisationen
Anestesiologi och intensivvård
I samma tidskrift
Biomedical Optics Express
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 64 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf