uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Depth-Resolved X-ray Absorption Spectroscopy by Means of Grazing Emission X-ray Fluorescence
Paul Scherrer Inst, CH-5232 Villigen, Switzerland..
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Kemiska sektionen, Institutionen för kemi - Ångström, Fysikalisk kemi. Polish Acad Sci, Inst Phys Chem, PL-01224 Warsaw, Poland..
Paul Scherrer Inst, CH-5232 Villigen, Switzerland.;Jan Kochanowski Univ Humanities & Sci, Inst Phys, PL-25406 Kielce, Poland..
2015 (Engelska)Ingår i: Analytical Chemistry, ISSN 0003-2700, E-ISSN 1520-6882, Vol. 87, nr 21, s. 10815-10821Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Grazing emission X-ray fluorescence (GEXRF) is well suited for nondestructive elemental-sensitive depth-profiling measurements on samples with nanometer-sized features. By varying the grazing emission angle under which the X-ray fluorescence signal is detected, the probed depth range can be tuned from a few to several hundred nanometers. The dependence of the XRF intensity on the grazing emission angle can be assessed in a sequence of measurements or in a scanning-free approach using a position-sensitive area detector. Hereafter, we will show that the combination of scanning-free GEXRF and fluorescence detected X-ray absorption spectroscopy (XAS) allows for depth-resolved chemical speciation measurements with nanometer-scale accuracy. While the conventional grazing emission geometry is advantageous to minimize self-absorption effects, the use of a scanning-free setup makes the sequential scanning of the grazing emission angles obsolete and paves the way toward time-resolved depth-sensitive XAS measurements. The presented experimental approach was applied to study the surface oxidation of an Fe layer on the top of bulk Si and of a Ge bulk sample. Thanks to the penetrating properties and the insensitivity toward the electric conduction properties of the incident and emitted X-rays, the presented experimental approach is well suited for in situ sample surface studies in the nanometer regime.

Ort, förlag, år, upplaga, sidor
2015. Vol. 87, nr 21, s. 10815-10821
Nationell ämneskategori
Fysikalisk kemi Analytisk kemi
Identifikatorer
URN: urn:nbn:se:uu:diva-268407DOI: 10.1021/acs.analchem.5b03346ISI: 000364354900026PubMedID: 26458105OAI: oai:DiVA.org:uu-268407DiVA, id: diva2:878475
Tillgänglig från: 2015-12-09 Skapad: 2015-12-04 Senast uppdaterad: 2017-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Sa, Jacinto

Sök vidare i DiVA

Av författaren/redaktören
Sa, Jacinto
Av organisationen
Fysikalisk kemi
I samma tidskrift
Analytical Chemistry
Fysikalisk kemiAnalytisk kemi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 663 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf