uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Measurement of specific IgE antibodies to Ses i 1 improves the diagnosis of sesame allergy
Kyoto Univ, Grad Sch Agr, Lab Food Qual Design & Dev, Uji, Kyoto 6110011, Japan..
Aichi Childrens Hlth & Med Ctr, Dept Allergy, Obu, Aichi, Japan..
Aichi Childrens Hlth & Med Ctr, Dept Allergy, Obu, Aichi, Japan..
Kyoto Univ, Grad Sch Agr, Lab Food Qual Design & Dev, Uji, Kyoto 6110011, Japan..
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: Clinical and Experimental Allergy, ISSN 0954-7894, E-ISSN 1365-2222, Vol. 46, nr 1, s. 163-171Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

Background The number of reported cases of allergic reactions to sesame seeds (Sesamum indicum) has increased significantly. The specific IgE tests and skin prick tests presently available for diagnosis of sesame allergy are all based on crude sesame extract and are limited by their low clinical specificity. Thus, oral food challenge (OFC) is still the gold standard in the diagnosis. Objective The aim was to identify the allergen components useful to diagnose sesame-allergic children with the goal to reduce the number of OFCs needed. Methods Ninety-two sesame-sensitized children were consecutively enrolled and diagnosed based on OFC or convincing history. Specific IgE to purified native 11S globulin (nSes i 11S), 7S globulin (nSes i 7S), 2S albumin (nSes i 2S), and two recombinant 2S albumins (rSes i 1 and rSes i 2) was measured by ELISA and/or ImmunoCAP (rSes i 1/streptavidin application). Results Based on area under curve (AUC) values from receiver operating characteristic (ROC) analysis, rSes i 1 was shown to have the best diagnostic performance of the allergen components in ELISA. The experimental rSes i 1 ImmunoCAP test had larger AUC (0.891; 95% CI, 0.826-0.955) compared to the commercially available sesame ImmunoCAP (0.697; 95% CI, 0.589-0.805). The clinical sensitivity and specificity for the rSes i 1 ImmunoCAP test at optimal cut-off (3.96 kUA/L) were 86.1% and 85.7%, respectively. Conclusion and Clinical Relevance Sensitization to Ses i 1 is strongly associated with clinical sesame allergy. Measurement of specific IgE to rSes i 1 could reduce the numbers of OFCs needed.

Ort, förlag, år, upplaga, sidor
2016. Vol. 46, nr 1, s. 163-171
Nyckelord [en]
2S albumin, molecular-based allergy diagnostics, oral food challenge, Ses i 1, sesame
Nationell ämneskategori
Lungmedicin och allergi
Identifikatorer
URN: urn:nbn:se:uu:diva-276829DOI: 10.1111/cea.12626ISI: 000367924500017PubMedID: 26310924OAI: oai:DiVA.org:uu-276829DiVA, id: diva2:903487
Tillgänglig från: 2016-02-16 Skapad: 2016-02-16 Senast uppdaterad: 2017-11-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Borres, Magnus P.Moverare, Robert

Sök vidare i DiVA

Av författaren/redaktören
Borres, Magnus P.Moverare, Robert
Av organisationen
PediatrikInstitutionen för medicinska vetenskaper
I samma tidskrift
Clinical and Experimental Allergy
Lungmedicin och allergi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 219 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf