Near-field dosimetry for the millimeter-wave exposure of human cells in vitro
2012 (Engelska)Ingår i: Bioelectromagnetics, ISSN 0197-8462, E-ISSN 1521-186X, s. 55-64Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Due to the expected mass deployment of millimeter-wave wireless technologies, thresholds of potential millimeter-wave-induced biological and health effects should be carefully assessed. The main purpose of this study is to propose, optimize, and characterize a near-field exposure configuration allowing illumination of cells in vitro at 60 GHz with power densities up to several tens of mW/cm(2) . Positioning of a tissue culture plate containing cells has been optimized in the near-field of a standard horn antenna operating at 60 GHz. The optimal position corresponds to the maximal mean-to-peak specific absorption rate (SAR) ratio over the cell monolayer, allowing the achievement of power densities up to 50 mW/cm(2) at least. Three complementary parameters have been determined and analyzed for the exposed cells, namely the power density, SAR, and temperature dynamics. The incident power density and SAR have been computed using the finite-difference time-domain (FDTD) method. The temperature dynamics at different locations inside the culture medium are measured and analyzed for various power densities. Local SAR, determined based on the initial rate of temperature rise, is in a good agreement with the computed SAR (maximal difference of 5%). For the optimized exposure setup configuration, 73% of cells are located within the ±3 dB region with respect to the average SAR. It is shown that under the considered exposure conditions, the maximal power density, local SAR, and temperature increments equal 57 mW/cm(2) , 1.4 kW/kg, and 6 °C, respectively, for the radiated power of 425 mW.

Ort, förlag, år, upplaga, sidor
2012. s. 55-64
Nationell ämneskategori
Annan medicinteknik
Identifikatorer
URN: urn:nbn:se:uu:diva-282909OAI: oai:DiVA.org:uu-282909DiVA, id: diva2:917785
Tillgänglig från: 2016-04-07 Skapad: 2016-04-07 Senast uppdaterad: 2017-11-30

Open Access i DiVA

Fulltext saknas i DiVA

Personposter BETA

Augustine, Robin

Sök vidare i DiVA

Av författaren/redaktören
Augustine, Robin
I samma tidskrift
Bioelectromagnetics
Annan medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 262 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf