Logotyp: till Uppsala universitets webbplats

uu.sePublikationer från Uppsala universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The importance of adjusting for differences in proximal and distal contrast bolus arrival times in contrast-enhanced iliac artery magnetic resonance angiography
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi. (RAD)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi. (RAD)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Vascular Surgery)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi. (RAD)
2003 (Engelska)Ingår i: European Radiology, ISSN 0938-7994, E-ISSN 1432-1084, Vol. 13, nr 5, s. 957-963Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We tested the hypothesis that differences in proximal and distal contrast bolus arrival times may result in insufficient vascular signal in the distal part of the aortoiliofemoral territory with routinely used timing techniques. The difference in arrival time of the contrast medium bolus between the aorta and the common femoral arteries was measured in 14 patients undergoing magnetic resonance angiography of the aortoiliac arteries. A dual-station test bolus technique adjusting for this difference was evaluated. The variation coefficient of the signal intensity in six defined locations and signal intensities (SI) normalised to fat were calculated. Comparisons were made with findings in 13 patients examined with a fluoroscopically triggered timing technique (BolusTrak, Philips Medical Systems, Best, The Netherlands). The difference in bolus arrival time between proximal and distal vessels was 0-7 s. In 3 of 14 patients it was 5.6-7 s. There was a tendency towards a lower mean variation coefficient in the dual-station group ( p=0.10). With both techniques, significantly lower SIs were measured in the femoral arteries compared with SIs in the superior part of the abdominal aorta. In two cases in the BolusTrak group, a distal vessel could not be delineated but was shown to be patent on a delayed scan. Differences in contrast medium arrival time along the vessel may be large enough to preclude visualisation of distal vessels unless there is compensation. A dual-station test bolus technique taking this into account was found to be feasible.

Ort, förlag, år, upplaga, sidor
2003. Vol. 13, nr 5, s. 957-963
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:uu:diva-65876DOI: 10.1007/s00330-002-1646-1PubMedID: 12695815OAI: oai:DiVA.org:uu-65876DiVA, id: diva2:93787
Tillgänglig från: 2008-10-17 Skapad: 2008-10-17 Senast uppdaterad: 2017-11-28Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed
Av organisationen
Enheten för radiologiInstitutionen för kirurgiska vetenskaper
I samma tidskrift
European Radiology
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 341 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf