Brain Perfusion Measurements Using Multidelay Arterial Spin-Labeling Are Systematically Biased by the Number of Delays.
Vise andre og tillknytning
2018 (engelsk)Inngår i: American Journal of Neuroradiology, ISSN 0195-6108, E-ISSN 1936-959X, Vol. 39, nr 8, s. 1432-1438Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND AND PURPOSE: Multidelay arterial spin-labeling is a promising emerging method in clinical practice. The effect of imaging parameters in multidelay arterial spin-labeling on estimated cerebral blood flow measurements remains unknown. We directly compared 3-delay versus 7-delay sequences, assessing the difference in the estimated transit time and blood flow.

MATERIALS AND METHODS: This study included 87 cognitively healthy controls (78.7 ± 3.8 years of age; 49 women). We assessed delay and transit time-uncorrected and transit time-corrected CBF maps. Data analysis included voxelwise permutation-based between-sequence comparisons of 3-delay versus 7-delay, within-sequence comparison of transit time-uncorrected versus transit time-corrected maps, and average CBF calculations in regions that have been shown to differ.

RESULTS: The 7-delay sequence estimated a higher CBF value than the 3-delay for the transit time-uncorrected and transit time-corrected maps in regions corresponding to the watershed areas (transit time-uncorrected = 27.62 ± 12.23 versus 24.58 ± 11.70 mL/min/100 g, Cohen's d = 0.25; transit time-corrected = 33.48 ± 14.92 versus 30.16 ± 14.32 mL/min/100 g, Cohen's d = 0.23). In the peripheral regions of the brain, the estimated delay was found to be longer for the 3-delay sequence (1.52408 ± 0.25236 seconds versus 1.47755 ± 0.24242 seconds, Cohen's d = 0.19), while the inverse was found in the center of the brain (1.39388 ± 0.22056 seconds versus 1.42565 ± 0.21872 seconds, Cohen's d = 0.14). Moreover, 7-delay had lower hemispheric asymmetry.

CONCLUSIONS: The results of this study support the necessity of standardizing acquisition parameters in multidelay arterial spin-labeling and identifying basic parameters as a confounding factor in CBF quantification studies. Our findings conclude that multidelay arterial spin-labeling sequences with a high number of delays estimate higher CBF values than those with a lower number of delays.

sted, utgiver, år, opplag, sider
2018. Vol. 39, nr 8, s. 1432-1438
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-357433DOI: 10.3174/ajnr.A5717PubMedID: 29976831OAI: oai:DiVA.org:uu-357433DiVA, id: diva2:1239375
Tilgjengelig fra: 2018-08-16 Laget: 2018-08-16 Sist oppdatert: 2018-11-08bibliografisk kontrollert

Open Access i DiVA

fulltext(1546 kB)30 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1546 kBChecksum SHA-512
defdb7f79cb87f9ff391325b1572285acb24f44f44623fd3fa759db5d7e356e0a4485b58eb97b8e1633d209e72d63bb00ebe09cf63f85a0cd8000ecb56d5329b
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Haller, Sven

Søk i DiVA

Av forfatter/redaktør
Haller, Sven
Av organisasjonen
I samme tidsskrift
American Journal of Neuroradiology

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 30 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 17 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf