Central Venous Line and Dialysis Catheter Position Affects Drug Clearance during Continuous Renal Replacement Therapy in an Animal Model.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård. Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, Centrum för klinisk forskning, Gävleborg.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Klinisk kemi.ORCID-id: 0000-0003-3161-0402
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård. Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Hedenstiernalaboratoriet.ORCID-id: 0000-0002-1976-4129
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: ASAIO journal (1992), ISSN 1058-2916, E-ISSN 1538-943X, Vol. 65, nr 4, s. 408-413Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In intensive care, drugs are commonly administered through central venous catheters (CVC). These catheters and central venous dialysis catheters (CVDC) are often placed in the same vessel for practical reasons. The aim of this experimental study was to investigate if the position of CVC and CVDC influences the elimination of infused drugs, during continuous renal replacement therapy (CRRT). In a randomized, cross-over model, anesthetized piglets received both a CVC and a CVDC in a jugular vein. Another CVDC was placed in a femoral vein for comparison. After baseline measurements, CRRT was performed in either of the CVDC, each CRRT-period separated by another baseline period. Hypotension was induced by peripherally given sodium nitroprusside. In the CVC, both gentamicin and noradrenaline were administered. Noradrenaline was titrated to reach a target blood pressure. When CRRT was performed using the CVDC in the same vessel as the drugs were infused, the plasma concentration of gentamicin was reduced compared with when the infusion and CVDC were in different vessels (5.66 [standard deviation (SD) ± 1.23] vs. 7.76 [SD ± 2.30] mg/L [p = 0.02]). The noradrenaline infusion rate needed to reach the target blood pressure was more than doubled (0.32 [SD ± 0.16] vs. 0.15 [SD ± 0.08] µg/kg/min [p = 0.006]). This experimental study indicates that the removal of drugs is increased if infusion is in close vicinity of the CVDC, during CRRT.

Ort, förlag, år, upplaga, sidor
2019. Vol. 65, nr 4, s. 408-413
Nationell ämneskategori
Anestesi och intensivvård
Identifikatorer
URN: urn:nbn:se:uu:diva-353342DOI: 10.1097/MAT.0000000000000839ISI: 000466791000022PubMedID: 29863633OAI: oai:DiVA.org:uu-353342DiVA, id: diva2:1257105
Forskningsfinansiär
Vetenskapsrådet, 523-2014-2569Tillgänglig från: 2018-10-18 Skapad: 2018-10-18 Senast uppdaterad: 2019-05-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Frithiof, RobertBandert, AnnaLarsson, AndersLipcsey, MiklósSmekal, David

Sök vidare i DiVA

Av författaren/redaktören
Frithiof, RobertBandert, AnnaLarsson, AndersLipcsey, MiklósSmekal, David
Av organisationen
Anestesiologi och intensivvårdCentrum för klinisk forskning, GävleborgKlinisk kemiHedenstiernalaboratoriet
I samma tidskrift
ASAIO journal (1992)
Anestesi och intensivvård

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 171 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf