Making grid capacity available through heat pump control
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper.
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper.
2019 (engelsk)Independent thesis Basic level (degree of Bachelor), 10 poäng / 15 hpOppgave
Abstract [en]

In this report the problem of constructing a bus depot with electrical buses despite the lack of grid capacity, was analyzed. A potential solution is investigated, namely smart control of heat pumps in industries. The possibility of allocating grid capacity to the bus depot by reducing power consumption in heat pumps during peak hours, is taken into consideration. The maximum amount of released capacity in an industrial area is calculated through the controlling of heat pumps. This investigation was made through simulations with a simplified building energy model (lumped capacity model) which was applied to a reference building.

After mapping the area Boländerna and the geothermal wells located there, IKEA Uppsala was chosen as the reference building, since a third of the total number of wells were found in that area. To take the whole capacity of Boländerna into account, the model was scaled up to estimate the total, possible reduction of power. The bus depot requires 6 MW nighttime and 4 MW daytime, the total amount of electrical power that could be withdrawn, if all heat pumps were on maximum heat, in the chosen area were 0.75 MW and by controlling the heat pumps during an optimized level, the amount of 142 kW could be made available to the electric grid. 142 kW is not enough cover the need for the bus depot but it could supply the need for a slow charger to one of the buses and is therefore a possible sub-solution to the larger problem.

sted, utgiver, år, opplag, sider
2019. , s. 34
Serie
TVE-STS ; 19005
Emneord [en]
Grid, capacity, electricity, Uppsala, IKEA, peak shaving, electric bus, bus depot, lumped capacity model, Region Uppsala
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-384182OAI: oai:DiVA.org:uu-384182DiVA, id: diva2:1319211
Eksternt samarbeid
Region Uppsala
Utdanningsprogram
Systems in Technology and Society Programme
Veileder
Examiner
Tilgjengelig fra: 2019-06-10 Laget: 2019-05-30 Sist oppdatert: 2019-06-10bibliografisk kontrollert

Open Access i DiVA

fulltext(1132 kB)19 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1132 kBChecksum SHA-512
cd649487e582d4702ef9bf8e2baf018127ce43abf71a5cb0d0f6092bb2960a4ee16a6ce77ac6a504b539bf8dc72097c1182319d51af75ce0f2b832380f288672
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 19 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 138 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf