Logo: to the web site of Uppsala University

uu.sePublikasjoner fra Uppsala universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A sensitive method detecting trace levels of levonorgestrel using LC-HRMS.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Klinisk kemi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kvinnors och barns hälsa, Forskargrupper (Inst. för kvinnor och barns hälsa), Reproduktionsbiologi.
Department of Marine Sciences, University of Gothenburg, Carl Skottbergs gata 22B, SE-41319 Gothenburg, Sweden..
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Klinisk farmakogenomik och osteoporos.
Vise andre og tillknytning
2019 (engelsk)Inngår i: Contraception, ISSN 0010-7824, E-ISSN 1879-0518, Vol. 100, nr 3, s. 247-249Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

OBJECTIVE: To develop a high resolution mass spectrometry (HRMS) method to quantify levonorgestrel (LNG) in serum.

STUDY DESIGN: Levonorgestrel was extracted using solid phase extraction and measured using liquid chromatography (LC) HRMS.

RESULTS: Low limit of quantification (LLOQ) was 25pg/mL and low limit of detection (LLOD) was 12.5pg/mL. Precision and accuracy bias were<10%. LNG in serum samples from Mirena® users ranged between 37 to 219pg/mL (n=12). In eight out of 22 patients with suspected intrauterine device (IUD) expulsion LNG was detected (26 to 1272pg/mL).

CONCLUSION: A sensitive, fast and simple LC-HRMS method was developed to detect trace levels of LNG.

sted, utgiver, år, opplag, sider
2019. Vol. 100, nr 3, s. 247-249
Emneord [en]
High resolution mass spectrometry, Intrauterine device, Liquid chromatography, Lower limit of quantification, Solid phase extraction
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-388593DOI: 10.1016/j.contraception.2019.06.001ISI: 000483452100015PubMedID: 31216423OAI: oai:DiVA.org:uu-388593DiVA, id: diva2:1334174
Tilgjengelig fra: 2019-07-02 Laget: 2019-07-02 Sist oppdatert: 2022-01-29bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Person

Olovsson, MattsRasmusson, AnnicaLarsson, AndersÅkerfeldt, TorbjörnKultima, Kim

Søk i DiVA

Av forfatter/redaktør
Abujrais, SandyOlovsson, MattsRasmusson, AnnicaLarsson, AndersÅkerfeldt, TorbjörnKultima, Kim
Av organisasjonen
I samme tidsskrift
Contraception

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 763 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf