Sensitivity of dynamic susceptibility contrast MRI to change in global flow rate
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Thoraxkirurgi.
Vise andre og tillknytning
(engelsk)Manuskript (preprint) (Annet vitenskapelig)
Emneord [en]
DSC-MRI, dynamic susceptibility contrast, MRI, perfusion
HSV kategori
Forskningsprogram
Radiologi
Identifikatorer
URN: urn:nbn:se:uu:diva-170530OAI: oai:DiVA.org:uu-170530DiVA, id: diva2:512719
Tilgjengelig fra: 2012-03-28 Laget: 2012-03-12 Sist oppdatert: 2015-06-11
Inngår i avhandling
1. Quantitative Tracer Based MRI Perfusion: Potentials and Limitations
Åpne denne publikasjonen i ny fane eller vindu >>Quantitative Tracer Based MRI Perfusion: Potentials and Limitations
2012 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Tracer based MRI perfusion measurements is a clinically useful tool to assess regional distributions of tissue blood flow and volume. The method may be based on any of the three relaxation mechanisms T1, T1 and T2*, the latter denoted DSC-MRI being the most common. The primary aim of this work was to study the feasibility of obtaining quantitative estimates using these methods.

1) Feasibility of DSC-MRI for kidneys using an iron oxide based contrast agent and the influence of secondary relaxation effects on the results, part of a clinical phase II trial: The method proved feasible and the underestimation induced by secondary relaxation can be corrected for by using a double echo sequence.

2) Influence of blood flow rate on risk factors for developing cerebral ischemia during cardio pulmonary bypass, measurements in pig with gadolinium based DSC-MRI: The results indicated an ischemic threshold level at a blood flow rate of approximately 6 ml/kg/min.

3) The ability of gadolinium based DSC-MRI to detect changes in global blood flow, experimental measurements in pig and numerical simulations: The results support that DSC-MRI can discriminate between global flow levels in the same subject given that all other parameters are kept constant. The results also indicate that calculated perfusion values are highly sensitive to the arterial deconvolution procedure.

4) Influence of differences in blood/tissue relaxivity and secondary relaxation for a gadolinium based contrast agent, measurements in pig and numerical simulations: The blood/tissue relaxivity ratio is not unity and the situation is complicated by secondary relaxation effects. Deconvolution regularization appears to partly counteract the overestimation induced by difference in blood/tissue relaxivity for DSC-MRI.

In summary, the fundamental assumption of equal blood and tissue relaxivity is experimentally shown to be invalid and the influence of this discrepancy is substantial. Several factors contribute to measurement errors, a combination of these factors can incidentally lead to additive errors or error cancellation based on a variety of experimental and analysis conditions. Given that the differences in blood/tissue relaxivity cannot readily be accounted for in a clinical setting, absolute perfusion quantification by tracer based MRI remains challenging if not impossible.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2012. s. 67
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 761
Emneord
MRI, Perfusion, Contrast agent, Relaxivity
HSV kategori
Forskningsprogram
Radiologi
Identifikatorer
urn:nbn:se:uu:diva-171901 (URN)978-91-554-8330-2 (ISBN)
Disputas
2012-05-16, Auditorium Minus, Museum Gustavianum, Akademigatan 3, Uppsala, 09:15 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2012-04-25 Laget: 2012-03-29 Sist oppdatert: 2012-08-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Morell, ArvidJonsson, OveTovedal, ThomasThelin, StefanAhlström, HåkanLennmyr, Fredrik

Søk i DiVA

Av forfatter/redaktør
Morell, ArvidJonsson, OveTovedal, ThomasThelin, StefanAhlström, HåkanLennmyr, Fredrik
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 528 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf