uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Exploring Co-57 as a new isotope for brachytherapy applications
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för biomedicinsk strålningsvetenskap.
2012 (Engelska)Ingår i: Medical physics (Lancaster), ISSN 0094-2405, Vol. 39, nr 5, s. 2342-2345Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: The characteristics of the radionuclide Co-57 make it interesting for use as a brachytherapy source. Co-57 combines a possible high specific activity with the emission of relatively low-energy photons and a half-life (272 days) suitable for regular source exchanges in an afterloader. Co-57 decays by electron capture to the stable Fe-57 with emission of 136 and 122 keV photons.

Methods: A hypothetical Co-57 source based on the Flexisource brachytherapy encapsulation with the active core set as a pure cobalt cylinder (length 3.5 mm and diameter 0.6 mm) covered with a cylindrical stainless-steel capsule (length 5 mm and thickness 0.125 mm) was simulated using Geant4 Monte Carlo (MC) code version 9.4. The radial dose function, g(r), and anisotropy function F(r,theta), for the line source approximation were calculated following the TG-43U1 formalism. The results were compared to well-known Ir-192 and 1(25)I radionuclides, representing the higher and the lower energy end of brachytherapy, respectively.

Results: The mean energy of photons in water, after passing through the core and the encapsulation material was 123 keV. This hypothetical Co-57 source has an increasing g(r) due to multiple scatter of low-energy photons, which results in a more uniform dose distribution than Ir-192.

Conclusions: Co-57 has many advantages compared to Ir-192 due to its low-energy gamma emissions without any electron contamination. Co-57 has an increasing g(r) that results in a more uniform dose distribution than Ir-192 due to its multiple scattered photons. The anisotropy of the Co-57 source is comparable to that of Ir-192. Furthermore, Co-57 has lower shielding requirements than Ir-192.

Ort, förlag, år, upplaga, sidor
2012. Vol. 39, nr 5, s. 2342-2345
Nyckelord [en]
brachytherapy, source, cobalt 57, Monte Carlo
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:uu:diva-175205DOI: 10.1118/1.3700171ISI: 000303604300004OAI: oai:DiVA.org:uu-175205DiVA, id: diva2:530971
Tillgänglig från: 2012-06-05 Skapad: 2012-06-04 Senast uppdaterad: 2017-12-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Lundqvist, Hans

Sök vidare i DiVA

Av författaren/redaktören
Lundqvist, Hans
Av organisationen
Enheten för biomedicinsk strålningsvetenskap
I samma tidskrift
Medical physics (Lancaster)
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 487 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf