uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Gadobenate dimeglumine (MultiHance) in MR angiography: an in-vitro phantom comparison with gadopentetate dimeglumine (Magnevist) at different concentrations
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för radiologi, onkologi och strålningsvetenskap, Enheten för radiologi.
2012 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 53, nr 10, s. 1112-1117Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background

Numerous clinical studies suggest that gadobenate dimeglumine is diagnostically superior to other gadolinium chelates for MR imaging applications, including contrast-enhanced MR angiography (CE-MRA). However, confirmatory in-vitro phantom studies have thus far been lacking.

Purpose

To evaluate the difference in signal intensity achieved with the high-relaxivity MR contrast agent gadobenate dimeglumine (MultiHance) relative to that achieved with the standard-relaxivity non-specific agent gadopentetate dimeglumine (Magnevist) at different concentrations using an in-vitro phantom study design.

Material and Methods

Test tubes with whole human blood were prepared with concentrations of gadobenate dimeglumine or gadopentetate dimeglumine ranging from 0 to 12 mM. A three-dimensional (3D) T1-weighted gradient echo sequence normally used for CE-MRA of the renal arteries was performed at flip angles of 25° and 35°. The signal-to-noise ratio (SNR) was calculated for all concentrations of both contrast agents. Furthermore a Look-Locker sequence was used and quantitative T1 mapping was performed for all the test tubes. The contrast agent concentration in the aorta was simulated using previously published data on T1 in the aorta during the first pass of a contrast agent. The differences between gadobenate dimeglumine and gadopentetate dimeglumine were compared at the simulated concentrations.

Results

The SNR achieved with gadobenate dimeglumine was consistently greater than that achieved with gadopentetate dimeglumine at all concentrations. An improvement of 15-25% in SNR was obtained when increasing the flip angle from 25° to 35°. The relative improvement in SNR with gadobenate dimeglumine relative to gadopentetate dimeglumine ranged from 25-72% and was markedly greater at lower concentrations with a flip angle of 35°.

Conclusion

Our findings suggest that the relative benefit of gadobenate dimeglumine over gadopentetate dimeglumine for CE-MRA applications is greater at lower concentrations.

Ort, förlag, år, upplaga, sidor
2012. Vol. 53, nr 10, s. 1112-1117
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-183658DOI: 10.1258/ar.2012.120181ISI: 000314077400007PubMedID: 23081961OAI: oai:DiVA.org:uu-183658DiVA, id: diva2:563662
Tillgänglig från: 2012-10-31 Skapad: 2012-10-31 Senast uppdaterad: 2017-12-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Johansson, LarsAhlström, Håkan

Sök vidare i DiVA

Av författaren/redaktören
Johansson, LarsAhlström, Håkan
Av organisationen
Enheten för radiologi
I samma tidskrift
Acta Radiologica
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 542 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf