Åsktransienter och överspänningar: En spänningsfylld simulering av elkraftsystemet vid Forsmark 3
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Elektricitetslära.
2014 (svensk)Independent thesis Advanced level (professional degree), 20 poäng / 30 hpOppgave
Abstract [en]

A power system will inevitably be subjected to transient overvoltages, most often produced by switching operations and lightning strikes. These transient overvoltages may harm sensitive equipment without sufficient protection, but it is not an easy task to predict what transients may occur or how they affect the system. A fault occurred in a low voltage system at Forsmark 2012 and overvoltages from lightning were concluded as the probable cause. The three aims with this thesis are to develop and test a model of the power system at Forsmark 3, analyse the transient behaviour of the system when subjected to lightning surges and identify critical parameters, and lastly to provide a tool for investigating the protection of the system. The modelling and simulations were performed in the freely available simulation program LT Spice. Challenges and difficulties have been to obtain parameter values for components that are relevant for the high frequencies produced by the short rise time in lightning surges. The main conclusions are: the maximum current in the lightning discharge has the largest impact on the system voltages and surges in the external grid can produce standing waves in the system, causing significant overvoltages even in low voltage systems. The simulations produced larger overvoltages than would occur in a real system, which also would dampen the high frequency signals to a larger extent. Further work to obtain models better suited for high frequency simulation is suggested.

sted, utgiver, år, opplag, sider
2014. , s. 33
Serie
UPTEC ES, ISSN 1650-8300 ; 14034
Emneord [sv]
kraftsystem, simulering, transient, överspänning, åska
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-231271OAI: oai:DiVA.org:uu-231271DiVA, id: diva2:744062
Eksternt samarbeid
Forsmark Kraftgrupp AB
Utdanningsprogram
Master Programme in Energy Systems Engineering
Veileder
Examiner
Tilgjengelig fra: 2014-09-11 Laget: 2014-09-05 Sist oppdatert: 2014-09-11bibliografisk kontrollert

Open Access i DiVA

EXAMENSARBETE ERIK AHLSTRÖM(2648 kB)763 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2648 kBChecksum SHA-512
22c7dc9733744543a1d88337510e1b8ab5a8e4b745e5d3b5a97c197c6b9dcc68c7684be1e753afdbc0bb1b79d9ad03810bfd240f37c36b5a264f8309bf604e9a
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 763 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1503 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf