Logo: to the web site of Uppsala University

uu.sePublikasjoner fra Uppsala universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Accuracy of GFR estimating equations combining standardized cystatin C and creatinine assays: a cross-sectional study in Sweden
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Biokemisk struktur och funktion.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper, Biokemisk struktur och funktion.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Clinical Chemistry and Laboratory Medicine, ISSN 1434-6621, E-ISSN 1437-4331, Vol. 53, nr 3, s. 403-414Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

 Background: The recently established international cystatin C calibrator makes it possible to develop non-laboratory specific glomerular filtration rate (GFR) estimating (eGFR) equations. This study compares the performance of the arithmetic mean of the revised Lund-Malmö creatinine and CAPA cystatin C equations (MEANLM-REV+CAPA), the arithmetic mean of the Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI) creatinine and cystatin C equations (MEANCKD-EPI), and the composite CKD-EPI equation (CKD-EPICREA+CYSC) with the corresponding single marker equations using internationally standardized calibrators for both cystatin C and creatinine.

Methods: The study included 1200 examinations in 1112 adult Swedish patients referred for measurement of GFR (mGFR) 2008-2010 by plasma clearance of iohexol (median 51 mL/min/1.73 m2). Bias, precision (interquartile range, IQR) and accuracy (percentage of estimates ±30% of mGFR; P30) were compared.

Results: Combined marker equations were unbiased and had higher precision and accuracy than single marker equations. Overall results of MEANLM-REV+CAPA/MEANCKD-EPI/CKD-EPICREA+CYSC were: median bias -2.2%/-0.5%/-1.6%, IQR 9.2/9.2/8.8 mL/min/1.73 m2, and P30 91.3%/91.0%/91.1%. The P30 figures were about 7-14 percentage points higher than the single marker equations. The combined equations also had a more stable performance across mGFR, age and BMI intervals, generally with P30 ≥90% and never <80%. Combined equations reached P30 of 95% when the difference between eGFRCREA and eGFRCYSC was <10% but decreased to 82% at a difference of ≥40%.

Conclusions: Combining cystatin C and creatinine assays improves GFR estimations with P30 ≥90% in adults. Reporting estimates of both single and combined marker equations in clinical settings makes it possible to assess the validity of the combined equation based on the agreement between the single marker equations.

sted, utgiver, år, opplag, sider
2015. Vol. 53, nr 3, s. 403-414
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-234308DOI: 10.1515/cclm-2014-0578ISI: 000349558500017PubMedID: 25274955OAI: oai:DiVA.org:uu-234308DiVA, id: diva2:756061
Merknad

Correction in: Clinical Chemistry and Laboratory Medicine, Volume 54, Issue 5 (May 2016). DOI: 10.1515/cclm-2014-0578_C

Tilgjengelig fra: 2014-10-16 Laget: 2014-10-16 Sist oppdatert: 2017-12-05bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Person

Larsson, Anders

Søk i DiVA

Av forfatter/redaktør
Larsson, Anders
Av organisasjonen
I samme tidsskrift
Clinical Chemistry and Laboratory Medicine

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 688 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf