Setting Thresholds to Varying Blood Pressure Monitoring Intervals Differentially Affects Risk Estimates Associated With White-Coat and Masked Hypertension in the Population
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Hypertension, ISSN 0194-911X, E-ISSN 1524-4563, Vol. 64, nr 5, s. 935-942Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Outcome-driven recommendations about time intervals during which ambulatory blood pressure should be measured to diagnose white-coat or masked hypertension are lacking. We cross-classified 8237 untreated participants (mean age, 50.7 years; 48.4% women) enrolled in 12 population studies, using >= 140/>= 90, >= 130/>= 80, >= 135/>= 85, and >= 120/>= 70 mm Hg as hypertension thresholds for conventional, 24-hour, daytime, and nighttime blood pressure. White-coat hypertension was hypertension on conventional measurement with ambulatory normotension, the opposite condition being masked hypertension. Intervals used for classification of participants were daytime, nighttime, and 24 hours, first considered separately, and next combined as 24 hours plus daytime or plus nighttime, or plus both. Depending on time intervals chosen, white-coat and masked hypertension frequencies ranged from 6.3% to 12.5% and from 9.7% to 19.6%, respectively. During 91 046 person-years, 729 participants experienced a cardiovascular event. In multivariable analyses with normotension during all intervals of the day as reference, hazard ratios associated with white-coat hypertension progressively weakened considering daytime only (1.38; P=0.033), nighttime only (1.43; P=0.0074), 24 hours only (1.21; P=0.20), 24 hours plus daytime (1.24; P=0.18), 24 hours plus nighttime (1.15; P=0.39), and 24 hours plus daytime and nighttime (1.16; P=0.41). The hazard ratios comparing masked hypertension with normotension were all significant (P<0.0001), ranging from 1.76 to 2.03. In conclusion, identification of truly low-risk white-coat hypertension requires setting thresholds simultaneously to 24 hours, daytime, and nighttime blood pressure. Although any time interval suffices to diagnose masked hypertension, as proposed in current guidelines, full 24-hour recordings remain standard in clinical practice.

Ort, förlag, år, upplaga, sidor
2014. Vol. 64, nr 5, s. 935-942
Nyckelord [en]
ambulatory blood pressure monitoring, cardiovascular risk, masked hypertension, population science, white-coat hypertension
Nationell ämneskategori
Kardiologi
Identifikatorer
URN: urn:nbn:se:uu:diva-237287DOI: 10.1161/HYPERTENSIONAHA.114.03614ISI: 000343593700010PubMedID: 25135185OAI: oai:DiVA.org:uu-237287DiVA, id: diva2:768363
Tillgänglig från: 2014-12-03 Skapad: 2014-12-01 Senast uppdaterad: 2017-12-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Lind, Lars

Sök vidare i DiVA

Av författaren/redaktören
Lind, Lars
Av organisationen
GeriatrikKardiovaskulär epidemiologi
I samma tidskrift
Hypertension
Kardiologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 762 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf