Manufacturing Miniature Langmuir probes by Fusing Platinum Bond Wires
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Mikrosystemteknik. (Ångström Space Technology Centre (ÅSTC))ORCID-id: 0000-0003-0832-1848
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Mikrosystemteknik. Swedish Defence University. (ÅSTC)ORCID-id: 0000-0002-0501-0887
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Mikrosystemteknik. (ÅSTC)
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Mikrosystemteknik. (ÅSTC)
2015 (engelsk)Inngår i: Journal of Micromechanics and Microengineering, ISSN 0960-1317, E-ISSN 1361-6439, Vol. 25, nr 10, artikkel-id 105012Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper reports on a novel method for manufacturing microscopic Langmuir probes with spherical tips from platinum bond wires for plasma characterization in microplasma sources by fusing. Here, the resulting endpoints, formed by droplets of a fused wire, are intended to act as a spherical Langmuir probe. For studying the fusing behavior, bond wires were wedge-bonded over a 2 mm wide slit, to emulate the final application, and fused at different currents and voltages. For electrical isolation, a set of wires were coated with a 4 µm thick layer of Parylene before they were fused. After fusing, the gap size, as well as the shape and area of the ends of the remaining stubs were measured. The yield of the process was also investigated, and the fusing event was studied using a high-speed camera for analyzing the dynamics of fusing. Four characteristic tip shapes were observed: spherical, semi-spherical, serpentine shaped and folded. The stub length leveled out at ~420µm. The fusing of the coated wires required a higher power for attaining a spherical shape. Finally, a Parylene coated bond wire was integrated into a stripline split-ring resonator (SSRR) microplasma source, and fused to form two Langmuir probes with spherical endpoints. These probes were used for measuring the I-V characteristics of a plasma generated by the SSRR. In a voltage range between -60 V and 60 V, the fused stubs exhibited the expected behavior of spherical Langmuir probes and will be considered for future integration.

sted, utgiver, år, opplag, sider
2015. Vol. 25, nr 10, artikkel-id 105012
Emneord [en]
Langmuir probe; bond wire; fusing; microplasma source
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot mikrosystemteknik
Identifikatorer
URN: urn:nbn:se:uu:diva-251306DOI: 10.1088/0960-1317/25/10/105012ISI: 000366827400028OAI: oai:DiVA.org:uu-251306DiVA, id: diva2:805315
Forskningsfinansiär
Swedish National Space BoardKnut and Alice Wallenberg FoundationTilgjengelig fra: 2015-04-15 Laget: 2015-04-15 Sist oppdatert: 2018-08-03bibliografisk kontrollert
Inngår i avhandling
1. Miniature Plasma Sources for High-Precision Molecular Spectroscopy in Planetary Exploration
Åpne denne publikasjonen i ny fane eller vindu >>Miniature Plasma Sources for High-Precision Molecular Spectroscopy in Planetary Exploration
2015 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The prospect of finding life outside Earth has fascinated mankind for ages, and new technology continuously pushes the boundary of how remote and how obscure evidence we can find. Employing smaller, or completely new, types of landers and robots, and equipping them with miniature instruments would indeed revolutionize exploration of other planets and moons.

In this thesis, microsystems technology is used to create a miniature high-precision isotope-resolving molecular spectrometer utilizing the optogalvanic effect. The heart of the instrument, as well as this thesis, is a microplasma source.

The plasma source is a split-ring resonator, chosen for its simplicity, pressure range and easily accessible plasma, and modified to fit the challenging application, e.g., by the adding of an additional ground plane for improved electromagnetic shielding, and the integration of microscopic plasma probes to extract the pristine optogalvanic signal.

Plasma sources of this kind have been manufactured in both printed circuit board and alumina, the latter for its chemical inertness and for compatibility with other devices in a total analysis system. From previous studies, classical optogalvanic spectroscopy (OGS), although being very sensitive, is known to suffer from stability and reproducibility issues. In this thesis several studies were conducted to investigate and improve these shortcomings, and to improve the signal-to-noise ratio. Moreover, extensive work was put into understanding the underlying physics of the technique.

The plasma sources developed here, are the first ever miniature devices to be used in OGS, and exhibits several benefits compared to traditional solutions. Furthermore, it has been confirmed that OGS scales well with miniaturization. For example, the signal strength does not decrease as the volume is reduced like in regular absorption spectroscopy. Moreover, the stability and reproducibility are greatly increased, in some cases as much as by two orders of magnitude, compared with recent studies made on a classical OGS setup. The signal-to-noise ratio has also been greatly improved, e.g., by enclosing the sample cell and by biasing the plasma. Another benefit of a miniature sample cell is the miniscule amount of sample it requires, which can be important in many applications where only small amounts of sample are available.

To conclude: With this work, an important step toward a miniature, yet highly performing, instrument for detection of extraterrestrial life, has been taken.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2015. s. 53
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1253
Emneord
MEMS, MST, Optogalvanic Spectroscopy, Molecular Spectroscopy, Split-Ring Resonator, Microplasma
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot mikrosystemteknik
Identifikatorer
urn:nbn:se:uu:diva-251315 (URN)978-91-554-9245-8 (ISBN)
Disputas
2015-06-05, Polhemsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:15 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2015-05-11 Laget: 2015-04-15 Sist oppdatert: 2015-07-07
2. Sense, Actuate and Survive: Ceramic Microsystems for High-Temperature Aerospace Applications
Åpne denne publikasjonen i ny fane eller vindu >>Sense, Actuate and Survive: Ceramic Microsystems for High-Temperature Aerospace Applications
2018 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

In aerospace applications, but also in manufacturing, mining, energy industry and natural hazards, high temperature, corrosion, erosion and radiation, challenge the performance and being of hardware.

In this work, high-temperature co-fired ceramic (HTCC) alumina and platinum have been used for a range of devices intended for aerospace applications at up to 1000°C.

The thermomechanics of a pressure sensor was investigated, and the interfacing was attained by wireless powering and reading. However, read range was limited and sensitivity decreased with temperature. Silver, electroplated after sintering, was found to remedy this until it eventually alloyed with platinum.

Copper was electroplated and oxidized for oxygen storage in a microcombustor, intended for sample preparation for optogalvanic spectroscopy (OGS) to indicate extraterrestrial life. Despite delamination, caused by residual stresses, the device operated successfully.

Conversely, pre-firing metallization by integration of platinum wires was studied. Freely suspended, and despite heat-induced shape irregularities, these were found advantageous over screen printed elements for gas heating, and temperature and pressure sensing. By fusing off the wires, spherical tips, allowing for impedance monitoring of microplasma sources in, e.g., OGS, were formed.

Microplasma sources can also be used for gas heating. This, together with screen printed and suspended resistive heaters, was evaluated in a microthruster, showing that plasma heating is the most effective, implying fuel consumption reduction in satellite propulsion.

In conclusion, HTCC alumina microdevices are thermally stable and could benefit several aerospace applications, especially with the complementary metallization schemes devised here.

Future developments are expected to include both processing and design, all with the intention of sensing, actuating and surviving in high-temperature environments.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis, 2018. s. 44
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1696
Emneord
High temperature, ceramics, microsystems, aerospace, sensors, thrusters
HSV kategori
Forskningsprogram
Teknisk fysik med inriktning mot mikrosystemteknik
Identifikatorer
urn:nbn:se:uu:diva-356692 (URN)978-91-513-0392-5 (ISBN)
Disputas
2018-09-21, Polhemsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:30 (svensk)
Opponent
Veileder
Tilgjengelig fra: 2018-08-31 Laget: 2018-08-03 Sist oppdatert: 2018-09-10

Open Access i DiVA

fulltext(4099 kB)262 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 4099 kBChecksum SHA-512
a0e169f2abcea94ac8f11a7929f28c17715ad7e212f65fbc2a7c3bc46ca2c7c58f66b7d47ca66e653039270c43e752cf663e9509143c6ca31d864f0188ad65a3
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Personposter BETA

Berglund, MartinSturesson, PeterThornell, GregerPersson, Anders

Søk i DiVA

Av forfatter/redaktør
Berglund, MartinSturesson, PeterThornell, GregerPersson, Anders
Av organisasjonen
I samme tidsskrift
Journal of Micromechanics and Microengineering

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 262 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 1516 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf