Effects of heparin coating of cardiopulmonary bypass circuits on in vitro oxygen free radical production during coronary bypass surgery
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Thoracic Surgery)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för medicinska vetenskaper.
Vise andre og tillknytning
1996 (engelsk)Inngår i: Artificial Organs, ISSN 0160-564X, E-ISSN 1525-1594, Vol. 20, nr 9, s. 1008-1016Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

During cardiopulmonary bypass (CPB) oxygen free radicals (OFR) are formed, which can mediate reactions damaging tissue components. Blood contact with artificial surfaces during CPB leads to an activation of leukocytes, which are one of the sources of the OFR. Heparin coating of the CPB circuit reduces granulocyte activation. In the present study, the heparin-coated circuits with noncoated cardiotomy reservoirs (Group HC) were compared with noncoated, otherwise similar CPB sets (Group C). In each group, 8 patients were operated on for coronary revascularization. The release of granulocyte granule proteins myeloperoxidase (MPO) and lactoferrin (LF) was evaluated. Production of OFR in the whole blood and in the granulocyte suspension were measured by chemiluminescence (CL). In both groups the whole blood CL declined during CPB. The whole blood CL induced by serum-opsonized zymosan, when enhanced by luminol, was significantly lower in Group HC at 45 min after CPB start (68 +/- 6% of initial values in Group HC vs. 87 +/- 6% in Group C, mean +/- SEM) and 30 min after protaminization (54 +/- 6% of initial values in Group HC vs. 72 +/- 6% in Group C, mean +/- SEM), and CL was significantly higher in Group HC at CPB end (83 +/- 5% of initial values in Group HC vs. 67 +/- 5% in Group C, mean +/- SEM) when enhanced by lucigenin. CL of isolated granulocytes showed no significant differences between the groups. Release of MPO at CPB end and of LF 45 min after start of CPB and at CPB end were significantly lower in the heparin-coated CPB circuits.

sted, utgiver, år, opplag, sider
1996. Vol. 20, nr 9, s. 1008-1016
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-55411PubMedID: 8864022OAI: oai:DiVA.org:uu-55411DiVA, id: diva2:83319
Tilgjengelig fra: 2008-10-17 Laget: 2008-10-17 Sist oppdatert: 2017-12-04bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

PubMed

Personposter BETA

Thelin, Stefan

Søk i DiVA

Av forfatter/redaktør
Thelin, Stefan
Av organisasjonen
I samme tidsskrift
Artificial Organs

Søk utenfor DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric

pubmed
urn-nbn
Totalt: 321 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf