Development of models for quantifying the environmental impact of demand response in electrical power distribution
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Industriell teknik.
2015 (engelsk)Independent thesis Advanced level (professional degree), 20 poäng / 30 hpOppgave
Abstract [en]

In this report some possible consequences of introducing demand response in the electric power grid are studied. Demand response is a part of the Smart Grid, which is a technology being developed to use our electric power grids more efficiently. Demand response programs aim to move people’s power usage over different times of the day, for example to distribute the power usage more evenly throughout the day or to permit a larger share of renewable, intermittent power sources in the system without making the delivery of electric power less stable.  A distribution system operator (DSO) can encourage customers to shift their power usage between different hours by various tariffs, for example by using time-differentiated or power dependent tariffs.

 

In this thesis, the change in power losses and possible environmental impact of introducing due to a power shift is studied. Power input curves from a DSO, Sala-Heby Energi AB, are studied and modified to simulate a power shift with an evened out electric power usage. The studies made show that in the best-case scenario, that is a electric power usage evened out to 100% each day, the power losses in the whole grid can be reduced with 2.6%. The environmental study shows that the result varies greatly with what method is chosen to do the calculations. The results are presented in kg CO2-equivalents (CO2e), and depending on method used they can either decrease or increase. The environmental study show that the environmental impact from the power usage is more dependent on the shift in power usage between hours than the decrease in electric power losses. 

sted, utgiver, år, opplag, sider
2015. , s. 45
Serie
UPTEC F, ISSN 1401-5757 ; 15028
Emneord [en]
smart grid, demand response, power loss
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-263282OAI: oai:DiVA.org:uu-263282DiVA, id: diva2:857706
Utdanningsprogram
Master Programme in Engineering Physics
Presentation
2015-06-15, 02:41 (svensk)
Veileder
Examiner
Tilgjengelig fra: 2015-10-27 Laget: 2015-09-30 Sist oppdatert: 2015-10-27bibliografisk kontrollert

Open Access i DiVA

karinandersson_thesis(3232 kB)433 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 3232 kBChecksum SHA-512
07e69f12ce135f13925afa0ad744baabc4350d058edd1afe560d8363a2169294d3a86b308099724dd4b5da918c52afb0980cf679e5e95aa025ecce2091ea72a9
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 433 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1158 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf