uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Improved extraction torque of hydroxyapatite-coated pedicle screws
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
2000 (Engelska)Ingår i: European spine journal, ISSN 0940-6719, E-ISSN 1432-0932, Vol. 9, nr 6, s. 534-7Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Loosening of the screws is a problem in instrumentation with pedicle screws. Coating with hydroxyapatite improves the holding characteristics for metal implants, but the possible effects on the anchorage of pedicle screws have not been described. In this study, seven patients were operated on with spinal instrumentation using four stainless steel pedicle screws. Hydroxyapatite-coated screws were used in either the upper or the lower of the instrumented levels. The insertion torque was measured. In four cases the screws were removed after 10-22 months and the extraction torque was measured. The mean insertion torque was found to be significantly greater in the hydroxyapatite-coated screws (107 Ncm) than in the standard screws (76 Ncm). In three cases, the extraction torque for the hydroxyapatite-coated screws exceeded the range for the torque wrench (600 Ncm), while the conventional screws were loose (< 5 Ncm). In one case, the extraction torque was 475 and 550 Ncm for the coated screws, and 5 and 25 Ncm for the conventional screws. The difference in extraction torque was significant. Hydroxyapatite coating was shown to have improved the purchase of pedicle screws very effectively. By using fully coated screws, as in the present study, extraction was extremely difficult compared to extraction of conventional stainless steel screws, which were regularly loose. By reducing the area of the screws that is coated, it may be possible to achieve an enhanced purchase while extraction will be easier when compared to fully coated screws.

Ort, förlag, år, upplaga, sidor
2000. Vol. 9, nr 6, s. 534-7
Nationell ämneskategori
Kirurgi
Forskningsämne
Ortopedi
Identifikatorer
URN: urn:nbn:se:uu:diva-58366DOI: 10.1007/s005860000180PubMedID: 11189923OAI: oai:DiVA.org:uu-58366DiVA, id: diva2:86276
Tillgänglig från: 2008-10-17 Skapad: 2008-10-17 Senast uppdaterad: 2017-12-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Olerud, ClaesLarsson, Sune

Sök vidare i DiVA

Av författaren/redaktören
Olerud, ClaesLarsson, Sune
Av organisationen
Ortopedi
I samma tidskrift
European spine journal
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 336 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf