uu.seUppsala universitets publikasjoner
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Magnetic nanobeads present during enzymatic amplification and labeling for a simplified DNA detection protocol based on AC susceptometry
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Fasta tillståndets fysik.
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Nanoteknologi och funktionella material.ORCID-id: 0000-0002-5496-9664
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Fasta tillståndets fysik.
Stockholm Univ, Dept Biochem & Biophys, Sci Life Lab, Solna, Sweden..
Vise andre og tillknytning
2015 (engelsk)Inngår i: AIP Advances, ISSN 2158-3226, E-ISSN 2158-3226, Vol. 5, nr 12, artikkel-id 127139Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

Magnetic biosensors are promising candidates for low-cost point-of-care biodiagnostic devices. For optimal efficiency it is crucial to minimize the time and complexity of the assay protocol including target recognition, amplification, labeling and read-out. In this work, possibilities for protocol simplifications for a DNA biodetection principle relying on hybridization of magnetic nanobeads to rolling circle amplification (RCA) products are investigated. The target DNA is recognized through a padlock ligation assay resulting in DNA circles serving as templates for the RCA process. It is found that beads can be present during amplification without noticeably interfering with the enzyme used for RCA (phi29 polymerase). As a result, the bead-coil hybridization can be performed immediately after amplification in a one-step manner at elevated temperature within a few minutes prior to read-out in an AC susceptometer setup, i.e. a combined protocol approach. Moreover, by recording the phase angle xi = arctan(chi ''/chi'), where chi and chi '' are the in-phase and out-of-phase components of the AC susceptibility, respectively, at one single frequency the total assay time for the optimized combined protocol would be no more than 1.5 hours, often a relevant time frame for diagnosis of cancer and infectious disease. Also, applying the phase angle method normalization of AC susceptibility data is not needed. These findings are useful for the development of point-of-care biodiagnostic devices relying on bead-coil binding and magnetic AC susceptometry.

sted, utgiver, år, opplag, sider
2015. Vol. 5, nr 12, artikkel-id 127139
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-275867DOI: 10.1063/1.4939570ISI: 000367596300039OAI: oai:DiVA.org:uu-275867DiVA, id: diva2:902623
Forskningsfinansiär
Swedish Research Council Formas, 221-2012-444, 2011-1692Swedish Foundation for Strategic Research , SBE13-0125Tilgjengelig fra: 2016-02-11 Laget: 2016-02-08 Sist oppdatert: 2019-04-24bibliografisk kontrollert

Open Access i DiVA

fulltext(747 kB)302 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 747 kBChecksum SHA-512
6494fe647c4a43e862560d14bf278e796fae7e0eb65b6d1318272b2c8b5762e54f676fee7fda1f494097c47258fb1ccd9bd19bff090706ba02f09bee98bd161c
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Personposter BETA

Bejhed Stjernberg, RebeccaStrömme, MariaSvedlindh, PeterStrömberg, Mattias

Søk i DiVA

Av forfatter/redaktør
Bejhed Stjernberg, RebeccaStrömme, MariaSvedlindh, PeterStrömberg, Mattias
Av organisasjonen
I samme tidsskrift
AIP Advances

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 302 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 772 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf