A new method of intrathecal PO2, PCO2, and pH measurements for continuous monitoring of spinal cord ischemia during thoracic aortic clamping in pigs
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Anaesthesiology and Intensive Care)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Vascular Surgery)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Anaesthesiology and Intensive Care)
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper. (Thoracic Surgery)
Vise andre og tillknytning
2000 (engelsk)Inngår i: Surgery, ISSN 0039-6060, E-ISSN 1532-7361, Vol. 127, nr 5, s. 571-576Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

BACKGROUND: Impaired spinal cord circulation during thoracic aortic clamping may result in paraplegia. Reliable and fast responding methods for intraoperative monitoring are needed to facilitate the evaluation of protective measures and efficiency of revascularization.

METHODS: In 11 pigs, a multiparameter PO2, PCO2, and pH sensor (Paratrend 7, Biomedical Sensors Ltd, United Kingdom) was introduced into the intrathecal space for continuous monitoring of cerebrospinal fluid (CSF) oxygenation during thoracic aortic cross-clamping (AXC) distal to the left subclavian artery. A laser-Doppler probe was inserted into the epidural space for simultaneous measurements of spinal cord flux. Registrations were made before and 30 minutes after clamping and 30 and 60 minutes after declamping. The same measuring points were used for systemic hemodynamic and metabolic data acquisition.

RESULTS: The mean CSF PO2 readings of 41 mm Hg (5.5 kPa) at baseline decreased within 3 minutes to 5 mm Hg (0.7 kPa) during AXC (P < .01). Spinal cord flux measurement responded immediately in the same way to AXC. Both methods indicated normalization of circulation during declamping. Significant (P < .01) changes were also observed in the CSF metabolic parameters PCO2 and pH.

CONCLUSIONS: In this experimental model of spinal ischemia by AXC, online monitoring of intrathecal PO2, PCO2, and pH showed significant changes and correlated well with epidural laser-Doppler flowmetry (P < .01).

sted, utgiver, år, opplag, sider
2000. Vol. 127, nr 5, s. 571-576
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-62364DOI: 10.1067/msy.2000.105036PubMedID: 10819067OAI: oai:DiVA.org:uu-62364DiVA, id: diva2:90275
Tilgjengelig fra: 2008-10-17 Laget: 2008-10-17 Sist oppdatert: 2017-11-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Christiansson, LennartThelin, StefanBergqvist, DavidWiklund, Lars

Søk i DiVA

Av forfatter/redaktør
Christiansson, LennartThelin, StefanBergqvist, DavidWiklund, Lars
Av organisasjonen
I samme tidsskrift
Surgery

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 433 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf