Hydroxyapatite coating enhances fixation of loaded pedicle screws: a mechanical in vivo study in sheep
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Ortopedi.
2001 (Engelska)Ingår i: European spine journal, ISSN 0940-6719, E-ISSN 1432-0932, Vol. 10, nr 4, s. 334-9Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Loosening of the pedicle screws with subsequent non-union or loss of correction is a frequent problem in spinal instrumentation. In a clinical pilot study, coating of pedicle screws with plasma-sprayed hydroxyapatite (HA) resulted in a significant increase of removal torque. An experimental study was performed to investigate the effects of HA coating on the pull-out resistance. Thirteen sheep were operated on with destabilising laminectomies at two levels, L2-L3 and L4-L5. Two instrumentations with four pedicle screws in each were used for stabilisation. Uncoated screws (stainless steel) or the same type of screws coated with plasma-sprayed HA were used in either the upper or the lower instrumentation in a randomised fashion. Four sheep were examined immediately after the application of the screws, three sheep at 6 weeks and four sheep at 12 weeks. Two sheep were euthanised early due to complications. The pull-out resistance was recorded in two HA-coated and two standard screws in each animal. The maximum pull-out resistance was higher for the HA-coated screws at 0 weeks (P< 0.02) and at 12 weeks (P<0.01) when compared to the uncoated screws, while there was no significant difference between the groups at 6 weeks. We believe that the higher pull-out resistance for HA-coated screws at 0 weeks was mainly caused by differences in surface roughness, while the difference at 12 weeks was due to a favourable bone reaction around the HA-coated screws. At 12 weeks, the average stiffness was significantly higher for the HA-coated screws, while there was no significant differences in stiffness between the two screw types at 0 and 6 weeks. Energy to failure was significantly higher for coated screws when compared to the uncoated screws at all three time points. HA coating improves fixation of loaded pedicle screws, with increased pull-out resistance and reduced risk of loosening.

Ort, förlag, år, upplaga, sidor
2001. Vol. 10, nr 4, s. 334-9
Nationell ämneskategori
Kirurgi
Identifikatorer
URN: urn:nbn:se:uu:diva-63168DOI: 10.1007/s005860100291PubMedID: 11563620OAI: oai:DiVA.org:uu-63168DiVA, id: diva2:91079
Tillgänglig från: 2008-10-17 Skapad: 2008-10-17 Senast uppdaterad: 2017-11-30Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Olerud, ClaesLarsson, Sune

Sök vidare i DiVA

Av författaren/redaktören
Olerud, ClaesLarsson, Sune
Av organisationen
Ortopedi
I samma tidskrift
European spine journal
Kirurgi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 355 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf