uu.seUppsala universitets publikationer
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Performance of the AGATA gamma-ray spectrometer in the PreSPEC set-up at GSI
Lund Univ, Dept Phys, SE-22100 Lund, Sweden.;GSI Helmholtzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany..
Tech Univ Darmstadt, Inst Kernphys, D-64289 Darmstadt, Germany..
CEA DSM CNRS IN2P3, GANIL, F-14076 Caen, France..
CSIC Univ Valencia, Inst Fis Corpuscular, E-46920 Valencia, Spain..
Visa övriga samt affilieringar
2016 (Engelska)Ingår i: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 806, s. 258-266Artikel i tidskrift (Refereegranskat) Published
Resurstyp
Text
Abstract [en]

In contemporary nuclear physics, the European Advanced GAmma Tracking Array (AGATA) represents a crucial detection system for cutting-edge nuclear structure studies. AGATA consists of highly segmented high-purity germanium crystals and uses the pulse-shape analysis technique to determine both the position and the energy of the y-ray interaction points in the crystals. It is the tracking algorithms that deploy this information and enable insight into the sequence of interactions, providing information on the full or partial absorption of the 7 ray. A series of dedicated performance measurements for an AGATA set-up comprising 21 crystals is described. This set-up was used within the recent PreSPEC-AGATA experimental campaign at the GSI Helmholtzzentrum fur Schwerionenforschung. Using the radioactive sources Co-56, Co-60 and Eu-152, absolute and normalized efficiencies and the peak-to-total of the array were measured. These quantities are discussed using different data analysis procedures. The quality of the pulse-shape analysis and the tracking algorithm are evaluated. The agreement between the experimental data and the Geant4 simulations is also investigated.

Ort, förlag, år, upplaga, sidor
2016. Vol. 806, s. 258-266
Nyckelord [en]
Gamma-ray spectroscopy, Gamma-ray tracking, Nuclear structure, Pulse shape analysis, HPGe detectors
Nationell ämneskategori
Fysik
Identifikatorer
URN: urn:nbn:se:uu:diva-270410DOI: 10.1016/j.nima.2015.10.032ISI: 000364856100035OAI: oai:DiVA.org:uu-270410DiVA, id: diva2:912001
Tillgänglig från: 2016-03-15 Skapad: 2015-12-28 Senast uppdaterad: 2017-11-30

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Nyberg, Johan

Sök vidare i DiVA

Av författaren/redaktören
Nyberg, Johan
Av organisationen
Institutionen för fysik och astronomiKärnfysik
I samma tidskrift
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 720 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf