Vindar med begränsad ventilation - Fukttekniska undersökningar
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper, Tillämpad mekanik, Byggteknik.
2016 (Svenska)Självständigt arbete på grundnivå (yrkesexamen), 10 poäng / 15 hpStudentuppsats (Examensarbete)
Abstract [en]

Tougher fire requirements and the desire to make

simpler designs have enabled construction companies

to go from the traditional well-ventilated attic to attic

with limited ventilation. Theoretically limited ventilated

winds should perform well. The problem you see if there

is construction moisture or external moisture sources.

Problems may occur when the small ventilation is not

able to remove moisture to the extent necessary.

Heavier constructions usually have a large amount of

construction moisture in the attic floor, which can be

transferred to the attic space. Heavier structures with

limited ventilated attics have not been studied

previously.

AK Consulting was commissioned to evaluate five attics

to a construction company erected in 2014 and 2015.

Former investigations showed that there was a risk

initially with respect to the excess moisture from

building moisture. This study was carried out with

theoretical calculations on a model of an existing attic

with moisture problems.

The present thesis was commissioned by AK

Consulting. It evaluated the data and reports from the

five attics and assesses them with the help of WUFI BIO

and made theoretical calculations in WUFI.

The study shows that attics with limited ventilations

work well initially and that the ventilation of the attic

does not lead to drier attics. Longer measurement

periods are required in order to see how the wind works

in the long term and in different outdoor climates. It is

difficult to determine the effect of initial

dehumidification of the winds. The attics have little or

no excess moisture over the measurement period.

The recommendations are to dehumidify attics initially

until further studies have been done on similar

structures. It is also important to continue monitoring

the attics in this study to follow up how they work in the

long term and during years with different climatic

conditions.

Ort, förlag, år, upplaga, sidor
2016.
Nationell ämneskategori
Husbyggnad
Identifikatorer
URN: urn:nbn:se:uu:diva-298216ISRN: UTH-INGUTB-EX-B-2016/03-SEOAI: oai:DiVA.org:uu-298216DiVA, id: diva2:945207
Utbildningsprogram
Högskoleingenjörsprogrammet i byggteknik
Handledare
Examinatorer
Tillgänglig från: 2016-07-04 Skapad: 2016-06-30 Senast uppdaterad: 2016-07-04Bibliografiskt granskad

Open Access i DiVA

fulltext(3749 kB)274 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 3749 kBChecksumma SHA-512
a21e760b047f40697b7fc26ec3a0150ef34a6c1b94396f9f53c6ef87715cd9ba7e7c9b968a5dea908ea66b1d9844aa81d623dbfbd833bc1c8b65ad0ca8d61abd
Typ fulltextMimetyp application/pdf

Av organisationen
Byggteknik
Husbyggnad

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 274 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 725 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf