Spot fluoroscopy: a novel innovative approach to reduce radiation dose in neurointerventional procedures
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi. Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Radiologi. Department of Medical Physics, Uppsala University Hospital, Uppsala, Sweden.
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för neurovetenskap, Neurokirurgi.ORCID-id: 0000-0001-6345-9415
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 58, nr 5, s. 600-608Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

BACKGROUND: Increased interest in radiation dose reduction in neurointerventional procedures has led to the development of a method called "spot fluoroscopy" (SF), which enables the operator to collimate a rectangular or square region of interest anywhere within the general field of view. This has potential advantages over conventional collimation, which is limited to symmetric collimation centered over the field of view.

PURPOSE: To evaluate the effect of SF on the radiation dose.

MATERIAL AND METHODS: Thirty-five patients with intracranial aneurysms were treated with endovascular coiling. SF was used in 16 patients and conventional fluoroscopy in 19. The following parameters were analyzed: the total fluoroscopic time, the total air kerma, the total fluoroscopic dose-area product, and the fluoroscopic dose-area product rate. Statistical differences were determined using the Welch's t-test.

RESULTS: The use of SF led to a reduction of 50% of the total fluoroscopic dose-area product (CF = 106.21 Gycm(2), SD = 99.06 Gycm(2) versus SF = 51.80 Gycm(2), SD = 21.03 Gycm(2), p = 0.003884) and significant reduction of the total fluoroscopic dose-area product rate (CF = 1.42 Gycm(2)/min, SD = 0.57 Gycm(2)/s versus SF = 0.83 Gycm(2)/min, SD = 0.37 Gycm(2)/min, p = 0.00106). The use of SF did not lead to an increase in fluoroscopy time or an increase in total fluoroscopic cumulative air kerma, regardless of collimation.

CONCLUSION: The SF function is a new and promising tool for reduction of the radiation dose during neurointerventional procedures.

Ort, förlag, år, upplaga, sidor
2017. Vol. 58, nr 5, s. 600-608
Nyckelord [en]
X-ray, collimation, digital subtraction angiography (DSA), neurointervention, fluoroscopy, dose saving
Nationell ämneskategori
Radiologi och bildbehandling
Identifikatorer
URN: urn:nbn:se:uu:diva-303911DOI: 10.1177/0284185116658682ISI: 000397475900013PubMedID: 27522095OAI: oai:DiVA.org:uu-303911DiVA, id: diva2:974578
Tillgänglig från: 2016-09-27 Skapad: 2016-09-27 Senast uppdaterad: 2017-08-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMed

Personposter BETA

Borota, LjubisaJangland, LarsRonne-Engström, ElisabethNyberg, ChristofferMahmoud, Ehab

Sök vidare i DiVA

Av författaren/redaktören
Borota, LjubisaJangland, LarsRonne-Engström, ElisabethNyberg, ChristofferMahmoud, Ehab
Av organisationen
RadiologiNeurokirurgi
I samma tidskrift
Acta Radiologica
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 632 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf