Detection of small implanted tumors growing during repeated magnetic resonance imaging of the rabbit liver: application of an interpretation model
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology.
Show others and affiliations
2004 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 45, no 5, 547-555 p.Article in journal (Refereed) Published
Abstract [en]

PURPOSE: To apply experimentally and further develop a new image interpretation model based on repeated imaging and aimed at improving assessments of technical efficacy and diagnostic accuracy in the detection of small lesions. MATERIAL AND METHODS: VX2 carcinoma was implanted in the liver of 14 rabbits as two 1.1-1.7 mm3 cores. Magnetic resonance imaging was performed before and 4 days after implantation and then every second day up to the 14th to 20th day. One T2-weighted sequence (TSE T2) and three T1-weighted sequences (SE T1, GE T1, and TFL T1) were used. Interpretation was performed stepwise: three readers independently interpreted image sequences chronologically (step 1). Tumors were included at the last examination (step 2). By concurrent interpretation of repeated examinations, the earliest day at which tumors became visible and tumor size were recorded (step 3). Records were corrected (step 4) and autopsy was performed (step 5). Two procedures for use in calculating repeated detection rates of tumors with different magnetic resonance imaging sequences are presented and discussed. RESULTS: Of 40 macroscopic tumors, 34 were included. They were mainly small (size range SE T1: 1-3mm, TSE T2: 1.5-5 mm) when they became visible as determined at step 3, which was consistently earlier than observed at step 1. TSE T2, SE T1, and GE T1 did not differ significantly regarding earliest day of detection (step 3), while TFL T1 revealed the tumors later. The initial repeated detection rates were higher with TSE T2 than with the other sequences. Frequency of false positives varied over time, indicating fluctuating criteria for reporting tumors. CONCLUSION: A theoretical image interpretation model previously described proved to be applicable for detection of experimental liver tumors. The model was improved by introducing calculations of repeated detection rates for initial image interpretation using an imaging reference standard.

Place, publisher, year, edition, pages
2004. Vol. 45, no 5, 547-555 p.
Keyword [en]
Animals, Comparative Study, False Positive Reactions, Female, Liver Neoplasms; Experimental/*diagnosis/pathology, Magnetic Resonance Imaging, Male, Models; Theoretical, Neoplasm Transplantation, Rabbits, Reference Standards, Sensitivity and Specificity, Tomography; X-Ray Computed
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-73035DOI: 10.1080/02841850410006164PubMedID: 15515518OAI: oai:DiVA.org:uu-73035DiVA: diva2:100946
Available from: 2007-04-18 Created: 2007-04-18 Last updated: 2010-06-03Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMedhttp://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed&cmd=Retrieve&list_uids=15515518&dopt=Citation

Search in DiVA

By author/editor
Jorulf, Håkan
By organisation
Department of Oncology, Radiology and Clinical Immunology
In the same journal
Acta Radiologica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 122 hits
ReferencesLink to record
Permanent link

Direct link