Position-dependent distribution of lung ventilation - A feasability study
Swisstom AG, Landquart, Switzerland..
Hosp Clin Univ, Dept Anesthesia & Crit Care, Valencia, Spain..
Hosp Univ Princesa, Dept Anesthesiol, Madrid, Spain..
Inst Invest Sanitaria Fdn Jimenez Diaz, Dept Crit Care, Madrid, Spain..
Show others and affiliations
2015 (English)In: 2015 IEEE Sensors Applications Symposium (SAS), 2015, 429-434 p.Conference paper, Published paper (Refereed)
Abstract [en]

The aim of this feasibility study was to determine whether the measurement setup and study protocol were able to show the effect that lung disease, body position and different levels of positive end expiratory pressure (PEEP) have on lung function. By means of a motorized rotation table and gravity sensors six pigs were rotated in steps of 30 degrees from left to right lateral position. Regional ventilation distributions, measured by electrical impedance tomography (EIT), oxygenation and compliance measurements were performed at each position. Both, experimental and measurement setup as well as the parameters chosen to characterize lung function appear suitable for analyzing the effects of PEEP and rotation in healthy and injured lungs. The initial results show that the distribution of regional ventilation was highly gravity-dependent especially in sick lungs. Furthermore lateral rotation showed significant recruitment effects on previously collapsed lung tissue as witnessed by the increases in oxygenation at all PEEPs.

Place, publisher, year, edition, pages
2015. 429-434 p.
Keyword [en]
EIT, electrical impedance tomography, lung function mechanical ventilation, oxygenation, PEEP, positive end expiratory pressure, rotation, recruitment, sensors
National Category
Medical Laboratory and Measurements Technologies
Identifiers
URN: urn:nbn:se:uu:diva-311108ISI: 000380510800078ISBN: 9781479961177 (print)OAI: oai:DiVA.org:uu-311108DiVA: diva2:1058499
Conference
IEEE Sensors Applications Symposium (SAS), APR 13-15, 2015, ZADAR, CROATIA
Available from: 2016-12-21 Created: 2016-12-21 Last updated: 2016-12-21Bibliographically approved

Open Access in DiVA

No full text

Search in DiVA

By author/editor
Suarez-Sipmann, Fernando
By organisation
Hedenstierna laboratory
Medical Laboratory and Measurements Technologies

Search outside of DiVA

GoogleGoogle Scholar

Total: 209 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf