uu.seUppsala University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Features of the First and Subsequent Return Strokes in Positive Ground Flashes based on Electric Field Measurements
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. Univ Teknol Mara, Fac Elect Engn, Ctr Elect Power Engn Studies, Shah Alam 40450, Selangor, Malaysia. (Åskforskning)
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. (Åskforskning)
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. (Åskforskning)
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. (Åskforskning)
Show others and affiliations
2017 (English)In: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 150, 55-62 p.Article in journal (Refereed) Published
Abstract [en]

This paper presents the characteristics of the electric fields produced by the first and the subsequent return strokes observed in positive ground flashes in Sweden. Fifty one positive ground flashes containing 60 return strokes recorded during 2014 summer thunderstorms were analyzed. In our analysis, only 12% of the cases were multiple-stroke while 88% were single-stroke. On average, the number of strokes per flash was 1.20 and the highest number of strokes per flash recorded was four. The geometric mean (GM) value of the interstroke interval was 60 ms while the distance between the first and the subsequent strokes ranged between 4.9 and 46.4km. We found that the average duration of the subsequent strokes parameters were smaller than that of the first strokes. For the first strokes, the GM values of the slow front duration, the fast transition 10-to-90% risetime, the zero crossing time, the zero-to-peak risetime and the 10-to-90% risetime were 8.7 mu s, 1.4 mu s, 29 mu s, 11 mu s and 5.7 mu s, respectively while for the subsequent strokes, the values were 4.0 mu s 0.91 mu s, 11 mu s 5.8 mu s and 3.2 mu s, respectively. Possible reasons for the shorter duration of the subsequent return strokes parameters were discussed.

Place, publisher, year, edition, pages
2017. Vol. 150, 55-62 p.
National Category
Meteorology and Atmospheric Sciences Engineering and Technology
Research subject
Engineering Science with specialization in Atmospheric Discharges
Identifiers
URN: urn:nbn:se:uu:diva-317450DOI: 10.1016/j.epsr.2017.04.031ISI: 000403744100006OAI: oai:DiVA.org:uu-317450DiVA: diva2:1081718
Available from: 2017-03-14 Created: 2017-03-14 Last updated: 2017-10-20Bibliographically approved
In thesis
1. Features of the Electric Fields Generated by Lightning with Special Attention to Positive Ground Flashes
Open this publication in new window or tab >>Features of the Electric Fields Generated by Lightning with Special Attention to Positive Ground Flashes
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

This thesis focuses on the main processes in positive ground flashes and the distant lightning environment for both positive and negative ground flashes. It presents the characteristics of the preliminary breakdown pulses (PBPs), the characteristics of the electric field pulses observed during leader propagation, and the characteristics of the electric fields produced by the first and the subsequent return strokes. It also features the observations of distant positive and negative ground flashes at distances up to 1000 km. The results were based on electric field measurements conducted remotely during summer thunderstorms in Sweden in 2014.

We found that the majority of the positive ground flashes were preceded by PBPs. Some were preceded by more than one PBP train, and the parameter values for the subsequent PBP trains were found to be smaller than the values for the first PBP train. Three types of PBPs were also identified. The results suggest that the PBPs in positive ground flashes during summer thunderstorms in Sweden are weak, and the inverted dipole charge cloud configuration is consistent with our observation.

A small percentage of these positive ground flashes were observed to be preceded by pronounced leader pulses. The presence of these pulses suggests that the leaders propagate in a stepped manner. We inferred that these pulses were due to the upward-connecting negative leader since their characteristics were similar to those of a negative stepped leader. On the basis of the leader pulses’ time of initiation and the average speed of the leader, we estimated the distance travelled by the leader. One case of positive return stroke preceded by negative leader pulses was also observed, and the occurrence of these pulses was the first in positive ground flashes to be reported.

The majority of these positive ground flashes were found to be single-stroke. Comparison between the first and the subsequent return strokes showed that the average durations of the subsequent stroke parameters were smaller than that of the first strokes. The distances reported by the lightning location system suggest that the subsequent strokes probably created new terminations to ground. Two possible reasons were given to explain the reason for the shorter duration of the subsequent return strokes parameters compared to the first strokes.

Finally, observations of distant positive and negative ground flashes showed that the electric field waveforms have a typical shape, like a distorted ‘W’ (or distorted ‘M’ for negative ground flashes) followed by small oscillations. These small oscillations were more pronounced in negative ground flashes, especially at a greater distance. The heights of the ionospheric reflections estimated for both ground flashes were found to likely correspond to a D-layer of the ionosphere. Two possible reasons were suggested for the small oscillations observed in the waveforms.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017. 49 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1588
Keyword
positive ground flashes, preliminary breakdown pulses, multiple-trains PBPs, positive leader, bidirectional leader, negative leader branch, subsequent return strokes, distant lightning
National Category
Meteorology and Atmospheric Sciences Engineering and Technology
Research subject
Engineering Science with specialization in Atmospheric Discharges
Identifiers
urn:nbn:se:uu:diva-331885 (URN)978-91-513-0128-0 (ISBN)
Public defence
2017-12-11, Häggsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:00 (English)
Opponent
Supervisors
Available from: 2017-11-20 Created: 2017-10-20 Last updated: 2017-11-20

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Johari, DalinaCooray, VernonRahman, MahbuburHettiarachchi, PasanIsmail, Mohd Muzafar

Search in DiVA

By author/editor
Johari, DalinaCooray, VernonRahman, MahbuburHettiarachchi, PasanIsmail, Mohd Muzafar
By organisation
Electricity
In the same journal
Electric power systems research
Meteorology and Atmospheric SciencesEngineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 293 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf