Correlation between regional cerebral blood flow based on simultaneously acquired arterial spin labelling MRI and 15O-water-PET using zero-echo-time-based attenuation correction
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
GE Healthcare, Stockholm, Sweden..
Show others and affiliations
2017 (English)In: Journal of Nuclear Medicine, ISSN 0161-5505, E-ISSN 1535-5667, Vol. 58, no S1, 362Article in journal, Meeting abstract (Other academic) Published
Abstract [en]

Objectives: Arterial spin labelling (ASL) MRI promises clinical value in several common neurological disorders. Its quantitative accuracy and reproducibility, however, need to be further validated, ideally using simultaneously acquired measurements with 15O-water-PET on an integrated PET-MR scanner. However, so far, few studies have attempted this and the inclusion of bone in MR-based attenuation correction for PET has thus far been a challenge, compromising the quantitative accuracy of PET-MR based 15O-water PET data. The aim of the present work was to assess the correlation of ASL- and 15O-water-PET based regional cerebral blood flow (rCBF) values based on simultaneously acquired data, using zero-echo-time (ZTE)-based attenuation correction, as well as to assess the reproducibility of ASL-based rCBF.

Methods: Six subjects underwent 10 min PET scans after automated bolus injection of 400 MBq 15O-water (1 mL/s during 5 s followed by 35 mL saline at 2 mL/s) on a time-of-flight integrated PET-MR scanner (Signa PET-MR, GE Healthcare). Arterial blood radioactivity concentrations were monitored using continuous sampling from the radial artery (Swisstrace Twilite Two). Simultaneously, a 3D FSE pseudo-continuous ASL (3D pCASL) with a spiral read-out as supplied by the scanner manufacturer in the commercial software were acquired using an 8 channel head coil (Invivo Hi-Res Head Coil). In addition, 3D T1-w, ZTE and Dixon fat-water MRI were acquired. The ASL procedure was repeated after 2 h (patients remained in the scanner). Quantifiable ASL-based CBF maps were generated. PET images were reconstructed into 26 frames of increasing durations using time-of-flight OSEM (2 iterations, 28 subsets) and a 5 mm post-filter, with ZTE-based attenuation correction. Blood sampler data were corrected for delay and dispersion and 15O-water-based CBF maps were calculated using a basis function implementation of the single tissue compartment model including a fitted blood volume parameter. CBF maps were co-registered to each patient's T1-w image. 3D T1-w images were segmented and normalised to MNI space using SPM12, and anterior, middle and posterior flow territory volumes of interest (VOIs) were created from a standard template in MNI space and inversely transformed for each patient. In addition, a 45-VOI probabilistic template was applied using PVElab software. Correlations between PET- and ASL-based rCBF values were assessed using regression analysis, and reproducibility of ASL using a paired t-test.

Results: Mean (CI) total brain grey matter CBF values were 67.2 (48.0-86.5) mL/min/100 g for 15O-water-PET and 65.5 (55.7-75.5) mL/min/100 g for ASL. Although correlation and agreement between 15O-water and ASL-based rCBF for individual VOIs in the 45-VOI template were generally poor, significant correlations were found on a grey matter flow territory basis, with R2 ranging from 0.70 in the anterior flow territory to 0.86 in the middle flow territory. rCBF values were significantly reduced between second and first ASL for all flow territories (p<0.01), with a mean decrease of 10%.

Conclusion: A good correlation between regional flow territory CBF values based on ASL and 15O-water-PET was found, using ZTE-based attenuation correction for PET data which takes bone tissue into account. ASL values for regional flow territories may have potential applications in patients with dementia or cerebrovascular diseases affecting blood flow such as moya moya. The decrease of ASL-based rCBF values in the reproducibility study needs to be investigated further to assess whether this is a methodological issue or reflects a true decrease in rCBF. Research Support: Uppsala County Council

Place, publisher, year, edition, pages
2017. Vol. 58, no S1, 362
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:uu:diva-333332ISI: 000404949901169OAI: oai:DiVA.org:uu-333332DiVA: diva2:1157096
Conference
Annual Meeting of the Society-of-Nuclear-Medicine-and-Molecular-Imaging (SNMMI), JUN 10-14, 2017, Denver, CO
Note

Title in WoS: Correlation between regional cerebral blood flow based on simultaneously acquired arterial spin labelling MRI and O-15-water-PET using zero-echo-time-based attenuation correction

Available from: 2017-11-15 Created: 2017-11-15 Last updated: 2017-11-15Bibliographically approved

Open Access in DiVA

No full text

Other links

http://jnm.snmjournals.org/content/58/supplement_1/362.abstract?sid=181cf22c-96f8-4412-8a58-b92e71974c60

Authority records BETA

Fahlström, MarkusAppel, LieuweAntoni, GunnarKumlien, EvaLarsson, Elna-MarieLubberink, Mark

Search in DiVA

By author/editor
Fahlström, MarkusAppel, LieuweAntoni, GunnarKumlien, EvaLarsson, Elna-MarieLubberink, Mark
By organisation
RadiologyDivision of Molecular ImagingNeurology
In the same journal
Journal of Nuclear Medicine
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 61 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf