Real-life clinical outcomes with everolimus eluting platinum chromium stent with an abluminal biodegradable polymer in patients from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology. (kardiologi)
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Cardiology. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center.
Show others and affiliations
2017 (English)In: Catheterization and cardiovascular interventions, ISSN 1522-1946, E-ISSN 1522-726X, Vol. 90, no 6, p. 881-887Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: No previous studies have evaluated the performance of the Synergy stent in a large real-life population.

OBJECTIVES: To describe the initial real-life experience with a novel everolimus eluting platinum chromium stent with abluminal biodegradable polymer (SYNERGY) in unselected patients from a nationwide registry.

METHODS: All implanted Synergy stents were compared with other new generation drug eluting stents (n-DES) with >1,000 implantations in Sweden between March 2013 and October 2015. Restenosis, definite stent thrombosis (ST), myocardial infarction (MI) and death rates were assessed using propensity score and Cox regression analyses.

RESULTS: A total of 7,886 of Synergy stents and 64,429 other n-DES (BioMatrix, N = 1,953; Orsiro, N = 4,946; Promus Element Plus, N= 2,543; Promus Premier, N= 20,414; Xience Xpedition, N= 7,971, Resolute/Resolute Integrity, N = 19,021; Ultimaster, N = 1,156; Resolute Onyx, N = 6,425) were implanted in 42,357 procedures. Restenosis and stent thrombosis occurred in 642 and 314 cases, respectively, in the overall population at 1 year. The cumulative rate of restenosis (1.1% vs. 1.0%, adjusted HR: 1.24 95% CI: 0.88-1.75; P = 0.21) and ST (0.4% vs. 0.5%, adjusted HR: 0.97; 95% CI: 0.63-1.50; P = 0.17) up to 1 year was low in both the Synergy group and the other n-DES group. Death occurred in 5.2% versus 4.5% (adjusted HR: 1.14; 95% CI: 0.96-1.36; P = 0.11) and MI in 3.2% versus 3.5%, (adjusted HR: 1.11; 95% CI: 0.93-1.33; P = 0.24) up to 1 year.

CONCLUSIONS: In a large real-life population the Synergy stent appears to be safe and effective with a low rate of restenosis and ST comparable with other n-DES.

Place, publisher, year, edition, pages
2017. Vol. 90, no 6, p. 881-887
Keywords [en]
drug eluting, percutaneous coronary intervention, restenosis, stent, stent thrombosis
National Category
Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:uu:diva-342858DOI: 10.1002/ccd.27030ISI: 000415694800002PubMedID: 28544146OAI: oai:DiVA.org:uu-342858DiVA, id: diva2:1185268
Available from: 2018-02-23 Created: 2018-02-23 Last updated: 2018-07-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Sarno, GiovannaLagerqvist, BoVarenhorst, ChristophLindholm, DanielJames, Stefan

Search in DiVA

By author/editor
Sarno, GiovannaLagerqvist, BoVarenhorst, ChristophLindholm, DanielJames, Stefan
By organisation
UCR-Uppsala Clinical Research CenterCardiology
In the same journal
Catheterization and cardiovascular interventions
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 3 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf