The 99th percentile and imprecision of point-of-care cardiac troponin I in comparison to central laboratory tests in a large reference population
Show others and affiliations
2017 (English)In: Clinical Biochemistry, ISSN 0009-9120, E-ISSN 1873-2933, Vol. 50, no 18, p. 1198-1202Article in journal (Refereed) Published
Abstract [en]

OBJECTIVES: Determination of cardiac troponin (cTn) is central in the emergency department (ED) for the diagnosis of myocardial infarction. In view of adverse effects of long waiting time on patient outcome, implementation of point-of-care-testing (POCT) is suggested if the turn-around-time is longer than 60min. The present study aimed to determine the 99th percentile and imprecision of two POCT in a healthy population measuring cTnI and cTnT and compare these analytical characteristics against three central laboratory test (CLT) for cTnI.

DESIGN & METHODS: CTnI and cTnT were determined in parallel by means of the AQT90 FLEX analyzer in about 2250 plasma samples from individuals with known health status. Results were compared to previously determined performance data of three CLT.

RESULTS: The 99th percentile of cTnI in the POCT was determined at 19ng/L, the lowest concentration with an imprecision of 10% was reached at 22ng/L while an imprecision of 20% was reached at 13ng/L. Age, sex, or physical activity did not affect the 99th percentile of cTnI. Compared to CLT the AQT90 cTnI POCT the analytical performance was equivalent. The cTnT POCT could not be assessed due a considerable number of high values and an inadequate imprecision profile.

CONCLUSION: While the cTnI POCT showed analytical performance comparable to CLT, the results of the cTnT assay on the same device did not suffice to determine a reliable 99th percentile. The present evaluation supports the usage of the cTnI POCT, but application of the cTnT POCT needs further evaluation.

Place, publisher, year, edition, pages
2017. Vol. 50, no 18, p. 1198-1202
Keywords [en]
99th reference percentile, AQT90, Analytical performance, Cardiac troponin I and T, Point-of-care
National Category
Clinical Laboratory Medicine
Identifiers
URN: urn:nbn:se:uu:diva-343469DOI: 10.1016/j.clinbiochem.2017.08.006ISI: 000415987300036PubMedID: 28803961OAI: oai:DiVA.org:uu-343469DiVA, id: diva2:1186150
Available from: 2018-02-27 Created: 2018-02-27 Last updated: 2018-02-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Lubenow, Norbert

Search in DiVA

By author/editor
Lubenow, Norbert
By organisation
Clinical Immunology
In the same journal
Clinical Biochemistry
Clinical Laboratory Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 9 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf