Variability in Heart-to-Mediastinum Ratio from Planar 123I-MIBG Images of a Thorax Phantom for 6 Common γ-Camera Models
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
GE Healthcare, Life Sci, Imaging R&D, Marlborough, MA USA..
GE Healthcare, Life Sci, Imaging R&D, Marlborough, MA USA..
2017 (English)In: Journal of Nuclear Medicine Technology, ISSN 0091-4916, E-ISSN 1535-5675, Vol. 45, no 4, p. 297-303Article in journal (Refereed) Published
Abstract [en]

A heart-to-mediastinum (H/M) ratio of 1.6 or greater on planar I-123-iobenguane (I-123-MIBG) images identifies heart failure patients at low risk of experiencing an adverse cardiac event. This phase-4 study used standardized phantoms to assess the intercamera, intracamera, and interhead variability in H/M ratio determinations from planar cardiac I-123-MIBG imaging using commercially available, dual-head.-cameras. Methods: A fillable thorax phantom was developed to simulate the typical uptake of I-123-MIBG. The phantom had a nominal H/M ratio of 1.6 on the reference camera. Commercial cameras used in the study were dual-head and capable of 90 degrees configuration for cardiac imaging. The target sample size was 8 units (examples) per camera model. Two imaging technologists independently analyzed planar images of simulated I-123-MIBG uptake from the thorax phantom. H/M was the ratio of the average counts per pixel of the heart and mediastinum regions of interest. The primary endpoint, intercamera variability in H/M ratio from head 1, was determined for each camera model via comparison with the H/M ratio on the reference camera. Only cameras with at least 8 units tested (n >= 8) were included in the primary analysis. Intracamera and interhead variability in the H/M ratio were also evaluated. Results: Nine camera models were studied. The mean H/M ratio ranged from 1.342 to 1.677. The primary analysis (6 camera models) using a mixed-model, repeated-measures analysis showed no significant difference in H/M ratio between any camera model and the reference camera. Intracamera variability (head 1) in the H/M ratio among camera models with 8 units or more was high, with SDs ranging from 0.0455 to 0.1193. Interhead variability was low (SDs of the interhead difference, 0.017-0.074). Conclusion: Commonly used.-cameras produced H/M ratios from simulated I-123-MIBG phantom images that were not significantly different from those on the reference camera. This finding indicates that the results of previous clinical trials of I-123-MIBG, involving many different clinical sites and camera models, are valid. The assessment of the performance of a given camera unit using an I-123 planar phantom before H/M results from I-123-MIBG imaging are used for classifying risk in heart failure patients is encouraged.

Place, publisher, year, edition, pages
2017. Vol. 45, no 4, p. 297-303
Keywords [en]
iobenguane, MIBG, phantom, heart-to-mediastinum ratio, heart failure
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:uu:diva-344217DOI: 10.2967/jnmt.117.196055ISI: 000416955400011PubMedID: 29042467OAI: oai:DiVA.org:uu-344217DiVA, id: diva2:1188034
Note

Title in WoS: Variability in Heart-to-Mediastinum Ratio from Planar I-123-MIBG Images of a Thorax Phantom for 6 Common gamma-Camera Models

Available from: 2018-03-06 Created: 2018-03-06 Last updated: 2018-03-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records BETA

Owenius, Rikard

Search in DiVA

By author/editor
Owenius, Rikard
By organisation
Radiology
In the same journal
Journal of Nuclear Medicine Technology
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf