uu.seUppsala University Publications
Change search
ReferencesLink to record
Permanent link

Direct link
The indoor environment in schools: Respiratory effects and air quality
Uppsala University, Medicinska vetenskapsområdet, Faculty of Medicine, Department of Medical Sciences.
2000 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The main objective of this work was to investigate relationships between the schoolenvironment and asthma and asthmatic symptoms in schoolchildren. Data on symptoms werecollected through postal questionnaires answered by 1,732 pupils in 39 randomly selectedschools, and were related to data on exposures obtained through hygienic measurements in theschools. Current asthma was more common in pupils attending a school with more openshelves in the classroom, more cat allergen in settled dust, and higher levels of formaldehyde,moulds and bacteria in the air. A follow-up study after 4 years showed that new onset ofasthma was more common in pupils who had attended a school with more settled dust, andmore cat allergen in the dust, and new pet allergy was related to higher concentrations ofrespirable dust. Among pupils without a history of atopy, new onset of asthma was morecommon in those who had attended a school with more formaldehyde or with a higherconcentration of total mould. In 1993, the Swedish ventilation standard was not reached in77 % of the investigated classrooms, and pupils attending schools where a new ventilationsystem was installed had a lower incidence of asthmatic symptoms compared to pupilsattending schools with no change of ventilation system. In a cross-sectional study amongschool employees it was found that half of the employees perceived the indoor air quality asbad, and this perception was related to higher concentrations of pollutants. The air exchangerate was the main predictor of the concentrations of pollutants in the school buildings. However, several of the pollutants that were important for asthmatic symptoms were alsorelated to characteristics of the classroom, such as fittings and furniture, and to the cleaningroutines. In conclusion, asthma and asthmatic symptoms in the pupils were related to factorsin the school environment. Settled dust, respirable dust, pet allergen, formaldehyde andmoulds were important. Several different measures should be undertaken when striving toreduce the concentrations in schools of pollutants with possible adverse health effects. Theventilation rate should be increased, the amount of fleecy or large-surface materials in theclassrooms minimised, and the cleaning of furniture and fabrics improved.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis , 2000. , 58 p.
Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 0282-7476 ; 925
Keyword [en]
Medical sciences, Allergy, asthma, cat allergen, cleaning, dust, formaldehyde, furniture, mould, schoolchildren, ventilation
Keyword [sv]
National Category
Medical and Health Sciences
Research subject
Occupational and Environmental Medicine
URN: urn:nbn:se:uu:diva-455ISBN: 91-554-4713-9OAI: oai:DiVA.org:uu-455DiVA: diva2:165091
Public defence
2000-05-22, Grönwallsalen, Akademiska sjukhuset, ingång 70, Uppsala, Uppsala, 13:00
Available from: 2000-05-01 Created: 2000-05-01Bibliographically approved

Open Access in DiVA

No full text
Buy this publication >>

By organisation
Department of Medical Sciences
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 434 hits
ReferencesLink to record
Permanent link

Direct link