Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Perioperative Continuous Noninvasive Cardiac Output Monitoring in Cardiac Surgery Patients by a Novel Capnodynamic Method
Hosp Privado Comunidad Mar Del Plata, Dept Anesthesiol, Mar Del Plata, Argentina..
Hosp Privado Comunidad Mar Del Plata, Dept Anesthesiol, Mar Del Plata, Argentina..
Karolinska Inst, Dept Physiol & Pharmacol, Sect Anesthesiol & Intens Care, Stockholm, Sweden.;Maquet Crit Care, Solna, Sweden..
Maquet Crit Care, Solna, Sweden..
Show others and affiliations
2022 (English)In: Journal of Cardiothoracic and Vascular Anesthesia, ISSN 1053-0770, E-ISSN 1532-8422, Vol. 36, no 8, p. 2900-2907Article in journal (Refereed) Published
Abstract [en]

Objectives

To test the clinical performance of a novel continuous noninvasive cardiac output (CO) monitoring based on expired carbon dioxide kinetics in cardiac surgery patients.

Design

A prospective feasibility pragmatic clinical study.

Setting

A single-center, large community hospital.

Participants

Thirty-two patients undergoing cardiac surgery were studied during the intraoperative (before cardiopulmonary bypass) and postoperative (in the intensive care unit before extubation) periods.

Interventions

CO was measured simultaneously by the continuous capnodynamic method and by transpulmonary thermodilution during changes in the patient's hemodynamic and/or respiratory conditions.

Measurements and Main Results

The current recommended comparative statistics for CO measurement methods were analyzed, including bias, precision, and percentage error obtained from Bland-Altman analysis, and concordance between methods obtained from the four-quadrant plot analysis to evaluate the trending ability. Bias ± limits of agreement and percentage error were –0.6 (–1.9 to +0.8; 95% CI of 3.73-5.25) L/min and 31% (n = 147 measurements) for the intraoperative period, –0.8 (–2.4 to +0.9; 95% CI of 3.03-5.21) L/min and 41% (n = 66) for the postoperative period, and –0.6 (–2.1 to +0.8; 95% CI of 3.74-5.00) L/min and 34% (n = 213) for the pooled data. The trending analysis obtained a concordance of 82% (n = 65) for the intraoperative and 71% (n = 24) for the early postoperative periods. Aggregation of both data sets gave a concordance of 79% (n = 89).

Conclusions

The continuous capnodynamic method was reliable and in good agreement with the reference method, and had an accuracy and trending ability good enough to make it a possible future alternative for hemodynamic monitoring in the studied population of elective adult cardiac surgery patients.

Place, publisher, year, edition, pages
Elsevier, 2022. Vol. 36, no 8, p. 2900-2907
Keywords [en]
carbon dioxide, capnography, cardiac output, monitoring, hemodynamics, cardiac surgery
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:uu:diva-488559DOI: 10.1053/j.jvca.2022.02.002ISI: 000885120800010PubMedID: 35283043OAI: oai:DiVA.org:uu-488559DiVA, id: diva2:1711845
Available from: 2022-11-18 Created: 2022-11-18 Last updated: 2023-04-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Suarez-Sipmann, Fernando

Search in DiVA

By author/editor
Suarez-Sipmann, Fernando
By organisation
Hedenstierna laboratory
In the same journal
Journal of Cardiothoracic and Vascular Anesthesia
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 46 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf