Development and verification of the pulsed scanned proton beam at the The Swedberg Laboratory in Uppsala
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology. (Protoner)
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology. (Protoner)
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology, Oncology. (Protoner)
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology. (Protoner)
Show others and affiliations
2007 (English)In: Physics in Medicine and Biology, ISSN 0031-9155, E-ISSN 1361-6560, Vol. 52, no 10, 2741-2754 p.Article in journal (Refereed) Published
Abstract [en]

In this paper we present the recent developments made for the scanning system for proton beams at TSL in Uppsala, showing that this system is now fully functional being able to produce conformal intensity modulated scan patterns with sufficient accuracy. A new control and supervising system handling the beam delivery including the control of the synchrocyclotron and the scanning system is developed and described in detail. A complete dosimetry system with transmission ionization chambers and a multi-wire ionization chamber for monitoring of the beam during scanning has been constructed. The details of the dose monitors and the position sensitive multi-wire ionization chamber are presented in this work. Furthermore, we have established procedures for verification measurements to ensure the quality of the beam and also methods for calibration of the beam monitors and relative and absolute dosimetry for complex scanned beams.

Place, publisher, year, edition, pages
2007. Vol. 52, no 10, 2741-2754 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:uu:diva-97033DOI: 10.1088/0031-9155/52/10/008ISI: 000246177000008PubMedID: 17473349OAI: oai:DiVA.org:uu-97033DiVA: diva2:171809
Available from: 2008-04-17 Created: 2008-04-17 Last updated: 2017-12-14Bibliographically approved
In thesis
1. Beam Modelling for Treatment Planning of Scanned Proton Beams
Open this publication in new window or tab >>Beam Modelling for Treatment Planning of Scanned Proton Beams
2008 (English)Doctoral thesis, comprehensive summary (Other academic)
Alternative title[sv]
Strålmodellering i dosplaneringssyfte för svepta protonstrålar
Abstract [en]

Scanned proton beams offer the possibility to take full advantage of the dose deposition properties of proton beams, i.e. the limited range and sharp peak at the end of the range, the Bragg peak. By actively scanning the proton beam, laterally by scanning magnets and longitudinally by shifting the energy, the position of the Bragg peak can be controlled in all three dimensions, thereby enabling high dose delivery to the target volume only. A typical scanned proton beam line consists of a pair of scanning magnets to perform the lateral beam scanning and possibly a range shifter and a multi-leaf collimator (MLC). Part of this thesis deals with the development of control, supervision and verification methods for the scanned proton beam line at the The Svedberg laboratory in Uppsala, Sweden.

Radiotherapy is preceded by treatment planning, where one of the main objectives is predicting the dose to the patient. The dose is calculated by a dose calculation engine and the accuracy of the results is of course dependent on the accuracy and sophistication of the transport and interaction models of the dose engine itself. But, for the dose distribution calculation to have any bearing on the reality, it needs to be started with relevant input in accordance with the beam that is emitted from the treatment machine. This input is provided by the beam model. As such, the beam model is the link between the reality (the treatment machine) and the treatment planning system. The beam model contains methods to characterise the treatment machine and provides the dose calculation with the reconstructed beam phase space, in some convenient representation. In order for a beam model to be applicable in a treatment planning system, its methods have to be general.

In this thesis, a beam model for a scanned proton beam is developed. The beam model contains models and descriptions of the beam modifying elements of a scanned proton beam line. Based on a well-defined set of generally applicable characterisation measurements, ten beam model parameters are extracted, describing the basic properties of the beam, i.e. the energy spectrum, the radial and the angular distributions and the nominal direction. Optional beam modifying elements such as a range shifter and an MLC are modelled by dedicated Monte Carlo calculation algorithms. The algorithm that describes the MLC contains a parameterisation of collimator scatter, in which the rather complex phase space of collimator scattered protons has been parameterised by a set of analytical functions.

Dose calculations based on the phase space reconstructed by the beam model are in good agreement with experimental data. This holds both for the dose distribution of the elementary pencil beam, reflecting the modelling of the basic properties of the scanned beam, as well as for complete calculations of collimated scanned fields.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2008. 56 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 330
Keyword
Radiation sciences, proton therapy, treatment planning, beam modelling, dose calculation, Monte Carlo, Strålningsvetenskap
Identifiers
urn:nbn:se:uu:diva-8640 (URN)978-91-554-7159-0 (ISBN)
Public defence
2008-05-09, Skoogsalen, Akademiska sjukhuset, ingång 78, Uppsala, 09:15
Opponent
Supervisors
Available from: 2008-04-17 Created: 2008-04-17 Last updated: 2013-09-19Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Tilly, NinaGrusell, ErikKimstrand, PeterLorin, StefanGajewski, KonradPettersson, MikaelBäcklund, AndreasGlimelius, Bengt

Search in DiVA

By author/editor
Tilly, NinaGrusell, ErikKimstrand, PeterLorin, StefanGajewski, KonradPettersson, MikaelBäcklund, AndreasGlimelius, Bengt
By organisation
Department of Oncology, Radiology and Clinical ImmunologyOncologyThe Svedberg Laboratory
In the same journal
Physics in Medicine and Biology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 506 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf