Gain stabilization control system of the upgraded magneticproton recoil neutron spectrometer at JET
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy, Applied Nuclear Physics.
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy, Applied Nuclear Physics.
Show others and affiliations
2009 (English)In: Review of Scientific Instruments, ISSN 0034-6748, E-ISSN 1089-7623, Vol. 80, no 6, 063505- p.Article in journal (Refereed) Published
Abstract [en]

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary forthe reliable operation of diagnostics. This paper describes the CM system of theupgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of thephotomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.

Place, publisher, year, edition, pages
2009. Vol. 80, no 6, 063505- p.
National Category
Natural Sciences
Identifiers
URN: urn:nbn:se:uu:diva-97574DOI: 10.1063/1.3109682ISI: 000267600600016OAI: oai:DiVA.org:uu-97574DiVA: diva2:172572
Available from: 2008-10-03 Created: 2008-10-03 Last updated: 2017-01-25Bibliographically approved
In thesis
1. Neutron Spectroscopy: Instrumentation and Methods for Fusion Plasmas
Open this publication in new window or tab >>Neutron Spectroscopy: Instrumentation and Methods for Fusion Plasmas
2008 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

When the heavy hydrogen isotopes deuterium (D) and tritium (T) undergo nuclear fusion large amounts of energy are released. At the Joint European Torus (JET) research is performed on how to harvest this energy. Two of the most important fusion reactions, d+d→3He+n (En = 2.5 MeV) and d+t→4He+n (En = 14 MeV), produce neutrons. This thesis investigates how measurements of these neutrons can provide information on the fusion performance.

The Magnetic Proton Recoil (MPR) neutron spectrometer has operated at JET since 1996. The spectrometer was designed to provide measurements on the 14 MeV neutron emission in DT operation, thereby conveying information on the state of the fuel ions. However, a majority of today’s fusion experiments are performed with pure D fuel. Under such conditions, the measurements with the MPR were severely hampered due to interfering background. This prompted an upgrade of the instrument. The upgrade, described in this thesis, included a new focal plane detector, a phoswich scintillator array, and new data acquisition electronics, based on transient recorder cards. This combination allows for pulse shape discrimination techniques to be applied and a signal to background of 5/1 has been achieved in measurements of the 2.5-MeV neutrons in D experiments. The upgrade also includes a new control and monitoring system, which enables the monitoring and correction of gain variations in the spectrometer’s photo multiplier tubes. Such corrections are vital for obtaining good data quality.

In addition, this thesis describes a new method for determining the total neutron yield and hence the fusion power by using a MPR spectrometer in combination with a neutron emission profile monitor. The system has been operated at JET both during DT and D experiments. It is found that the systematic uncertainties are considerably lower (≈6 %) than for traditional systems. For a dedicated system designed for the next generation fusion experiments, i.e, ITER, uncertainties of 4 % could be attained.

Neutron spectroscopy can also be an important tool for determining the neutron emission from residual tritium in D plasmas. This information is combined with other measurements at JET in order to determine the confinement of the 1 MeV tritons from the d+d→t+p reactions.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2008. 74 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 556
Keyword
Neutron spectroscopy, plasma diagnostics, fusion power, fusion, plasma heating, MPRu, JET, triton burn-up, ITER, neutron yield, calibration
National Category
Fusion, Plasma and Space Physics
Identifiers
urn:nbn:se:uu:diva-9296 (URN)978-91-554-7292-4 (ISBN)
Public defence
2008-10-24, Polhemsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:15
Opponent
Supervisors
Available from: 2008-10-03 Created: 2008-10-03 Last updated: 2011-01-12Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

Sjöstrand, HenrikConroy, SeanEricsson, GöranHellesen, CarlHjalmarsson, AndersWeiszflog, Matthias

Search in DiVA

By author/editor
Sjöstrand, HenrikConroy, SeanEricsson, GöranHellesen, CarlHjalmarsson, AndersWeiszflog, Matthias
By organisation
Department of Physics and AstronomyDepartment of Physics and AstronomyApplied Nuclear Physics
In the same journal
Review of Scientific Instruments
Natural Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 460 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf