First evaluation of six nucleic acid amplification tests widely used in the diagnosis of Chlamydia trachomatis in Russia
Show others and affiliations
2009 (English)In: Journal of the European Academy of Dermatology and Venereology, ISSN 0926-9959, E-ISSN 1468-3083, Vol. 23, no 3, 268-276 p.Article in journal (Refereed) Published
Abstract [en]

Abstract Background In Russia, nationally developed nucleic acid amplification tests (NAATs), which have never been validated to international commercially available NAATs, are mainly used in the diagnosis of Chlamydia trachomatis infection. Objective To evaluate the performance characteristics of six NAATs widely used to diagnose C. trachomatis infection in Russia. Materials and methods In total, 446 consecutive symptomatic patients (319 females and 127 males) were included. Five polymerase chain reaction (PCR) assays and one real-time nucleic acid sequence-based amplification (NASBA) assay were evaluated on cervical and vaginal samples from females and on urethral and first voided urine samples from males. As reference methods, the Cobas Amplicor PCR, as the main 'gold standard' method, and LightMix 480HT PCR were used. Results The overall prevalence of C. trachomatis infection was 12.6%. The Russian NAATs and the reference methods displayed a high level of concordance (97.9% to 99.2%). In comparison with the reference methods, the sensitivities, specificities, positive predictive values and negative predictive values of the Russian tests in different specimens ranged from 86.1% to 100%, 99.1% to 100%, 92.3% to 100% and 98.2% to 100%, respectively. Conclusions According to the reference methods, C. trachomatis NAATs developed and used in Russia have relatively good performance characteristics for both invasive and non-invasive samples. However, larger studies that include symptomatic and asymptomatic patients as well as genital and extra-genital samples, and in comparison with other internationally well-recognized, validated, and ideally Food and Drug Administration-approved C. trachomatis NAATs performed strictly according to the manufacturer's instructions, need to be conducted. Conflicts of interest None declared.

Place, publisher, year, edition, pages
2009. Vol. 23, no 3, 268-276 p.
Keyword [en]
Chlamydia trachomatis, LightMix 480HT, nucleic acid amplification tests (NAATs), Roche Cobas Amplicor, Russia, sensitivity and specificity
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-102213DOI: 10.1111/j.1468-3083.2008.03038.xISI: 000263496000005PubMedID: 19207643OAI: oai:DiVA.org:uu-102213DiVA: diva2:214526
Available from: 2009-05-05 Created: 2009-05-05 Last updated: 2010-08-27Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
By organisation
Clinical Bacteriology
In the same journal
Journal of the European Academy of Dermatology and Venereology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 201 hits
ReferencesLink to record
Permanent link

Direct link