Long-term safety and efficacy of drug-eluting versus bare-metal stents in Sweden
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, UCR-Uppsala Clinical Research Center.
Show others and affiliations
2009 (English)In: New England Journal of Medicine, ISSN 0028-4793, Vol. 360, no 19, 1933-1945 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: The long-term safety and efficacy of drug-eluting coronary stents have been questioned. METHODS: We evaluated 47,967 patients in Sweden who received a coronary stent and were entered into the Swedish Coronary Angiography and Angioplasty Registry between 2003 and 2006 and for whom complete follow-up data were available for 1 to 5 years (mean, 2.7). In the primary analysis, we compared patients who received one drug-eluting coronary stent (10,294 patients) with those who received one bare-metal stent (18,659), after adjustment for differences in clinical characteristics of the patients and characteristics of the vessels and lesions. RESULTS: Analyses of outcome were based on 2380 deaths and 3198 myocardial infarctions. There was no overall difference between the group that received drug-eluting stents and the group that received bare-metal stents in the combined end point of death or myocardial infarction (relative risk with drug-eluting stents, 0.96; 95% confidence interval [CI], 0.89 to 1.03) or the individual end points of death (relative risk, 0.94; 95% CI, 0.85 to 1.05) and myocardial infarction (relative risk, 0.97; 95% CI, 0.88 to 1.06), and there was no significant difference in outcome among subgroups stratified according to the indication for stent implantation. Patients who received drug-eluting stents in 2003 had a significantly higher rate of late events than patients who received bare-metal stents in the same year, but we did not observe any difference in outcome among patients treated in later years. The average rate of restenosis during the first year was 3.0 events per 100 patient-years with drug-eluting stents versus 4.7 with bare-metal stents (adjusted relative risk, 0.43; 95% CI, 0.36 to 0.52); 39 patients would need to be treated with drug-eluting stents to prevent one case of restenosis. Among high-risk patients, the adjusted risk of restenosis was 74% lower with drug-eluting stents than with bare-metal stents, and only 10 lesions would need to be treated to prevent one case of restenosis. CONCLUSIONS: As compared with bare-metal stents, drug-eluting stents are associated with a similar long-term incidence of death or myocardial infarction and provide a clinically important decrease in the rate of restenosis among high-risk patients.

Place, publisher, year, edition, pages
2009. Vol. 360, no 19, 1933-1945 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-105108DOI: 10.1056/NEJMoa0809902ISI: 000265784400004PubMedID: 19420363OAI: oai:DiVA.org:uu-105108DiVA: diva2:220514
Available from: 2009-06-01 Created: 2009-06-01 Last updated: 2012-07-05Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
James, Stefan K.Wallentin, LarsLagerqvist, Bo
By organisation
UCR-Uppsala Clinical Research Center
In the same journal
New England Journal of Medicine
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available