Short and long term biocompatibility of NeuroProbes silicon probes
Uppsala University, Disciplinary Domain of Science and Technology, Physics, Department of Physics and Astronomy.
Show others and affiliations
2010 (English)In: Journal of Neuroscience Methods, ISSN 0165-0270, E-ISSN 1872-678X, Vol. 189, no 2, 216-229 p.Article in journal (Refereed) Published
Abstract [en]

Brain implants provide exceptional tools to understand and restore cerebral functions. The utility of these devices depends crucially on their biocompatibility and long term viability. We addressed these points by implanting non-functional, NeuroProbes silicon probes, without or with hyaluronic acid (Hya), dextran (Dex), dexamethasone (DexM), Hya + DexM coating, into rat neocortex. Light and transmission electron microscopy were used to investigate neuronal survival and glial response. The surface of explanted probes was examined in the scanning electron microscope. We show that blood vessel disruption during implantation could induce considerable tissue damage. If, however, probes could be inserted without major bleeding, light microscopical evidence of damage to surrounding neocortical tissue was much reduced. At distances less than 100 mu m from the probe track a considerable neuron loss (similar to 40%) occurred at short survival times, while the neuronal numbers recovered close to control levels at longer survival. Slight gliosis was observed at both short and long term survivals. Electron microscopy showed neuronal cell bodies and synapses close (<10 mu m) to the probe track when bleeding could be avoided. The explanted probes were usually partly covered by tissue residue containing cells with different morphology. Our data suggest that NeuroProbes silicon probes are highly biocompatible. If major blood vessel disruption can be avoided, the low neuronal cell loss and gliosis should provide good recording and stimulating results with future functional probes. We found that different bioactive molecule coatings had small differential effects on neural cell numbers and gliosis, with optimal results achieved using the DexM coated probes. (C) 2010 Elsevier B.V. All rights reserved.

Place, publisher, year, edition, pages
2010. Vol. 189, no 2, 216-229 p.
Keyword [en]
Silicon probes, Rat neocortex, Neuron density, Glial reaction, Surface treatment
National Category
Medical and Health Sciences Engineering and Technology
URN: urn:nbn:se:uu:diva-136148DOI: 10.1016/j.jneumeth.2010.04.009ISI: 000279088700010OAI: oai:DiVA.org:uu-136148DiVA: diva2:376458
Available from: 2010-12-10 Created: 2010-12-10 Last updated: 2010-12-10Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Department of Physics and Astronomy
In the same journal
Journal of Neuroscience Methods
Medical and Health SciencesEngineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 147 hits
ReferencesLink to record
Permanent link

Direct link